Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
oxidising liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study and GLP

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report date:
2015

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.21 (Oxidising Properties (Liquids))
Qualifier:
according to guideline
Guideline:
other: O.2 (for liquids) of the Manual of test and Criteria of the UN-Recommendations on the transport of dangerous Goods
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Reference substance name:
Phosphoric acid, mono C16-20 (branched, even numbered) alkyl esters
Molecular formula:
unspecified
IUPAC Name:
Phosphoric acid, mono C16-20 (branched, even numbered) alkyl esters

Results and discussion

Test results (Oxidising liquids)open allclose all
Key result
Sample tested:
test mixture (not specified)
Remarks:
migrated information
Parameter:
mean pressure rise time
Remarks on result:
other: result not specified (migrated information)
Remarks:
The test item mixed with cellulose: Because the upper limit value of 20.7 bar was not reached, a mean pressure rise time could not be determined.
Key result
Sample tested:
reference mixture (not specified)
Remarks:
migrated information
Parameter:
mean pressure rise time
Result:
4 149 ms

Applicant's summary and conclusion

Interpretation of results:
other: no oxidising properties
Remarks:
Migrated information
Conclusions:
The test item can be classified as non oxidising substance.