Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study was conducted in an EU-based laboratory. The study was conducted in accordance with a recognised OECD test guideline.
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
no
GLP compliance:
no
Type of method:
air comparison pycnometer (for solids)
Type:
relative density
Density:
2.83
Temp.:
20 °C
Remarks on result:
other: Average of 2.8323 and 2.8334
Conclusions:
The relative density was found to be 2.83
Executive summary:

The relative density of the substance was determined in accordance with OECD test guideline 109 using a air comparison pycnometer with helium. The relative density was found to be 2.83

Description of key information

The relative density was found to be 2.83

Key value for chemical safety assessment

Relative density at 20C:
2.83

Additional information

The relative density of the substance was determined in accordance with OECD test guideline 109 using an air comparison pycnometer with helium. The relative density was found to be 2.83