Administrative data

Endpoint:
viscosity
Type of information:
migrated information: read-across from supporting substance (structural analogue or surrogate)
Adequacy of study:
supporting study
Study period:
Between 12 February and 21 April 2012.
Reliability:
4 (not assignable)
Rationale for reliability incl. deficiencies:
other: Cited from ECHA disseminated dossier Query date: 2015-07-22 For justification of read across please refer to IUCLID section 13.

Data source

Reference
Reference Type:
other: ECHA disseminated dossier
Title:
No information
Report date:
2015

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Deviations:
no
GLP compliance:
yes
Type of method:
capillary viscometer (static)

Test material

Constituent 1
Reference substance name:
939-183-5
EC Number:
939-183-5
IUPAC Name:
939-183-5
Details on test material:
Identification: ERC#18
Description: clear colorless liquid
Batch: 9114460/002
Purity: 100% (UVCB)
Expiry / Retest Date: 23 January 2013
Storage Conditions: room temperature in the dark

Results and discussion

Viscosityopen allclose all
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
6.01
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
10.9

Any other information on results incl. tables

Results

Calibration Check

The results for are shown in the following table:

 

Table 1

 

Determination

Temperature (ºC)

Time (s)

Viscosity
  (mm2/s)

Mean
Experimental Viscosity (mm2/s)

Certified   Viscosity Standard Value
(mm2/s)

A

25.0 ± 0.5

503

4.87

4.88

4.92

B

25.0 ± 0.5

505

4.89

 

Test Item Determinations

The results are shown in the following table:

 

Table 2

 

Determination

Temperature (ºC)

Time (s)

Viscosity (mm2/s)

Mean Viscosity (mm2/s)

A

20.0 ± 0.5

1131

10.9

10.9

B

1129

10.9

A

40.0 ± 0.5

618

5.98

6.01

B

624

6.04

 

Conclusion

The viscosity of the test item has been determined at 20.0 ºC and 40.0 ºC. The results are shown in the following table:

 

Table 3

Temperature (ºC)

Viscosity (mm2/s)

20.0 ± 0.5

10.9

40.0 ± 0.5

6.01

Applicant's summary and conclusion

Conclusions:
The viscosity of the test item has been determined at 20.0 ºC and 40.0 ºC. The results are shown in the table within the Executive Summary Section under the heading Conclusion.
Executive summary:

Test System

The determination was carried out using the capillary viscometer method and a procedure designed to be compatible with Method 114 of the OECD Guidelines for Testing of Chemicals, 12 May 1981.

Test Item Determinations

The results are shown in the following table:

 

Table 1

 

Determination

Temperature (ºC)

Time (s)

Viscosity (mm2/s)

Mean Viscosity (mm2/s)

A

20.0 ± 0.5

1131

10.9

10.9

B

1129

10.9

A

40.0 ± 0.5

618

5.98

6.01

B

624

6.04

Conclusion

The viscosity of the test item has been determined at 20.0 ºC and 40.0 ºC. The results are shown in the following table:

 

Table 2

Temperature (ºC)

Viscosity (mm2/s)

20.0 ± 0.5

10.9

40.0 ± 0.5

6.01