Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
20 May - 29 July
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP Guideline Study (EC Method A.9)
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Principles of method if other than guideline:
not applicable
GLP compliance:
yes (incl. QA statement)
Type of method:
equilibrium method closed cup
Flash point:
> 104 °C
Atm. press.:
1 atm

The test item has been determined not to have a flash point below its boiling temperature.

Conclusions:
The test item has been determined not to have a flash point below its boiling temperature.
Executive summary:

The flash point was determined using a closed cup equilibrium method, Testing was conducted using a method designed to be compatible with Method Ag Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008. The test item has been determined not to have a flash point below its boiling temperature.

Description of key information

No flash point below boiling temperature

Key value for chemical safety assessment

Additional information