Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

D50 = 12 µm
All matrix particles, in which the test substance was included, were greater than 100 µm.

Additional information

The particle size distribution was determined by laser diffraction measurement in a GLP-study according to OECD 110.

The particle size of the artificial substrate showed particles < 100 µm, while for the matrix particles only sizes greater than 100 µm were observed. Since the test substance is only imported as already included into the matrix, only particles > 100 µm have to be taken into account.