Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
toxicity to microorganisms, other
Remarks:
O2 consumption
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1984
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study with acceptable restrictions
Qualifier:
equivalent or similar to guideline
Guideline:
other: Method B-21
Principles of method if other than guideline:
O2 consumption test
GLP compliance:
no
Specific details on test material used for the study:
None
Analytical monitoring:
no
Details on sampling:
not applicable
Vehicle:
not specified
Details on test solutions:
no data
Test organisms (species):
activated sludge
Details on inoculum:
no data
Test type:
static
Water media type:
freshwater
Limit test:
no
Total exposure duration:
3 h
Remarks on exposure duration:
none
Post exposure observation period:
not applicable
Hardness:
no data
Test temperature:
no data
pH:
no data
Dissolved oxygen:
no data
Salinity:
no data
Nominal and measured concentrations:
Nominal: 10, 32 and 100 mg/L
Details on test conditions:
no data
Reference substance (positive control):
yes
Remarks:
3,5-dichlorophenol
Duration:
3 h
Dose descriptor:
IC50
Effect conc.:
90 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
other: O2 consumption
Details on results:
none
Results with reference substance (positive control):
3h IC50 = 18 mg/L based on 02 consumption
Reported statistics and error estimates:
not applicable

 Test-Substance (mg/L)

 O2 consumption

 % Inhibition

 100

 0.32

 50.8

 32

 0.36

 44.7

 10

 0.36

 44.7

Reference substance : 3,5-Dichlorphenol

 Test-Substance (mg/L)

 O2 consumption

 % Inhibition

 100

 0.08

 87.7

 32

 0.10

 84.7

 10

 0.56

 13.9

Validity criteria fulfilled:
not specified
Conclusions:
The 3 h IC50 for the test substance was found to be 90 mg/L (nominal).
Executive summary:

A study was conducted according to Method B-21 to determine the toxicity of the test substance (at ca. 80.5% purity) to activated sludge after an exposure of 3 h at concentration 10, 32 and 100 mg/L. Toxicity was evaluated based on reduction of O2 consumption. The reference substance 3, 5 -dichlorophenol was tested in parallel.

The 3 h IC50 for the test substance was found to be 90 mg/L (nominal). The 3 h IC50 for the reference substance was found to be 18 mg/L.

Description of key information

The study selected as key study was conducted to determine the toxicity of the test substance (at ca. 80.5 % purity) to activated sludge after an exposure of 3 h at concentration 10, 32 and 100 mg/L. Toxicity was evaluated based on reduction of O2 consumption. The reference substance 3, 5 -dichlorophenol was tested in parallel.

The 3 h IC50 for the test substance was equivalent to 90 mg/L (nominal). The 3 h IC50 for the reference substance was 18 mg/L.

Other supporting studies results are available, the results of which are presented below:

FAT 20003/H : 3h IC50 : . 400 mg/L

FAT 20003/G : 21d IC50 : > 300 mg/L.

FAT 20003/F : 21d IC50 : > 300 mg/L.

FAT 20003/D : 21d IC50 : > 300 mg/L

Key value for chemical safety assessment

EC50 for microorganisms:
90 mg/L

Additional information