Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
10-08-2018 to 21-08-2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study performed under GLP. All relevant validity criteria were met.
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
inspected: July 2017; signature: November 2017
Type of method:
pycnometer method
Type:
relative density
Density:
1.02 other: dimensionless
Temp.:
20.2 °C
Remarks on result:
other: mean relative density; Temperature: ± 0.5°C
Type:
density
Density:
1 020 kg/m³
Temp.:
20.02 °C
Remarks on result:
other: mean density; Temperature: ± 0.5°C

Table 1.0 – Pycnometer method determinations

Measurement

Determination

1

2

Mass of pycnometer (g)

17.0595

17.4369

Mass of pycnometer and purified water at 20.0 °C (g)

27.2304

27.6560

Mass of pycnometer and test item at 20.0 °C (g)

27.4294

27.8543

Density of water at 20.0 °C (kg/m3)

998.20

998.20

Density (kg/m3)

1.020

1020

Relative density

1.02

1.02

 

Mean density: 1020 kg/m^3

Mean relative density: 1.020

Temperature: 20.0 ± 0.5 °C

Conclusions:
The mean relative density of the test item was determined to be 1.02 at 20 ± 0.5 °C using the pycnometer method.
Executive summary:

The mean relative density was determined according to EU Method A.3 and OECD TG 109 using the pycnometer method under GLP. The mean relative density (n=2) of the test item was determined to be 1.02 at 20 ± 0.5 °C.

Description of key information

Relative Density: 1.02 at 20 ± 0.5 °C, EU Method A.3 pycnometer method, 2018

Key value for chemical safety assessment

Relative density at 20C:
1.02

Additional information

The mean relative density was determined according to EU Method A.3 and OECD TG 109 using the pycnometer method under GLP. The mean relative density (n=2) of the test item was determined to be 1.02 at 20 ± 0.5 °C.