Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 2017-11-22 to 2018-08-16
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: EU method A.24 (Partition coefficient - HPLC method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7570 (Partition Coefficient, n-octanol / H2O, Estimation by Liquid Chromatography)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient - HPLC Method)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Specific details on test material used for the study:
- Batch n°: I16FD3167
- Analytical purity: 98.2%
- Expiration date: 26 October 2018 (retest date)
- Storage condition: In refrigerator (2-8°C)
Analytical method:
high-performance liquid chromatography
photometric method
Key result
Type:
log Pow
Partition coefficient:
< 0.3
pH:
7
Remarks on result:
other: The temperature of the refernce substances was not reported but room temperature is assumed
Details on results:
Calculation method
The Pow of the test item was calculated to be < 2.0 (log Pow <0.3) using the Rekker calculation method.
No pKa values for acidic and basic groups in the molecular structure of the test item in the logarithm range of 1-14 were calculated.

Main study
In the chromatogram of all test solutions, responses with a retention time of approx. 0.6 min were observed.
Under the same analytical conditions, the retention time of 2-butanone (log Pow = 0.3) was 0.72 min. Hence, it was concluded that the log Pow of the test item and the log Pow of its aqueous degradation product was <0.3 (Pow < 2.0).

Pow of the test item at neutrual pH

 Substance  tr,1 [min]   tr,2[min]  mean tr (n=2)  log Pow  Pow
 Test solution 1  0.617  0.617  0.617 <0.3   <2.0
 Test solution 2  0.593 0.562   0.578  <0.3  <2.0
 Test solution 3  0.643  0.645  0.644  <0.3  <2.0
Conclusions:
The HPLC method at pH 7 was applied for the determination of the partition coefficient (Pow) of JNJ-26144612-AAA (T002632).
The Pow value of the test item at pH 7 was <2.0. This corresponds to a log Pow value of <0.3.

Description of key information

The partition coefficient was determined in a GLP study performed according to OECD Guideline 117, EU Method A.8. and EPA OPPTS 830.7550 (K1, Reingruber, 2019) using the HPLC method at pH 7. The Pow value of the test item at pH 7 was determined to be <2.0. This corresponds to a log Pow value of <0.3.

Key value for chemical safety assessment

Additional information

log Pow value of <0.3