Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Oxidising properties

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
oxidising solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
17 Dec 2018 to 25 Jan 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test O.1 (Test for oxidizing solids)
Version / remarks:
2015
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
Physical Description: Off-white powder (determined by Charles River Den Bosch)
Purity/Composition: 99.77%, assumed 100% for testing
Storage Conditions: At room temperature protected from light desiccated
Contact with:
powdered cellulose
Duration of test (contact time):
180 s
Key result
Sample tested:
4:1 sample-to-cellulose ratio
Parameter:
mean burning time
Result:
> 180 s
Key result
Sample tested:
1:1 sample-to-cellulose ratio
Parameter:
mean burning time
Result:
> 180 s
Interpretation of results:
GHS criteria not met
Conclusions:
The full test was performed to monitor the oxidizing properties of Esacure 1001 M.

Based on the results obtained it was concluded that the test item has no oxidizing properties and is therefore not classified as a Division 5.1 substance.
Executive summary:

In this guideline (UN O.1) study, with GLP certification, the test item was shown to not be classified as an oxidizing substance (Division 5.1) under GHS.

Description of key information

Study conducted to recognised testing guidelines with GLP certification.

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

Justification for classification or non-classification

Based on the results obtained it was concluded that the test item has no oxidizing properties and is therefore not classified as a Division 5.1 substance.