Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
07 Jun 2018 to 12 Sep 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient - HPLC Method)
Version / remarks:
30 May 2008
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Version / remarks:
13 April 2004
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Analytical method:
high-performance liquid chromatography
mass spectrometry
Key result
Type:
log Pow
Partition coefficient:
> 6.5
Temp.:
25 °C
pH:
6.5
Details on results:
See 'Any other information on results incl. tables' for an overview of the analytical results.

The retention times, capacity factor and log10 Pow value determined for the sample are shown in the following table:

Peak

Identity

Injection

Retention

Time (mins)

Capacity

Factor

(k')

Log10k'

Log10Pow

Mean

Log10POW

Partition

Coefficient

Peak 1

1

23.320

> 7.98

> 902

> 6.5

> 6.5

> 3.16 x 106

2

23.313

> 7.98

> 902

> 6.5

Peak 2

1

23.649

> 7.98

> 902

> 6.5

> 6.5

> 3.16 x 106

2

23.652

> 7.98

> 902

> 6.5

Peak 3

1

23.901

> 7.98

> 902

> 6.5

> 6.5

> 3.16 x 106

2

23.902

> 7.98

> 902

> 6.5

DISCUSSION

It was considered that the HPLC method would be the most suitable for determination of partition coefficient. As the test item contains no environmentally relevant dissociation constants, testing was performed at approximately neutral pH (eluent A: THF : Purified water (50:50 v/v), pH 6.5). The test item was eluted from the column after the retention time of DDT using eluent B (THF : 0.05 M ammonium formate, 0.2% formic acid, 0.1% trifluoroacetic acid (90:10 v/v). Acidified eluent was used to ionize the test item for MS detection.

Conclusions:
The partition coefficient of the test item has been determined to be greater than 3.16E6 (log Pow >6.5). 
Executive summary:

The octanol-water partition coefficient (Log Pow) of that test item was determined based on the HPLC Method, using a procedure designed to be compatible with OECD TG 117 and in compliance with GLP. The octanol-water partition coefficient (Log Pow) of test substance was greater than 6.5

Description of key information

log Pow > 6.5 at 25 °C, compatible with OECD 117, HPLC method, Butler 2018

Key value for chemical safety assessment

Additional information