Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Melting point / freezing point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
21 February 2017 to 22 August 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
differential scanning calorimetry
Key result
Melting / freezing pt.:
> 600 °C
Atm. press.:
101.325 kPa
Decomposition:
no
Sublimation:
no
Remarks on result:
other: No melting point was recorded up to 600°C.

Assay No. 1 (isotherm at 25°C for 5 min, heating ramp: 25°C to 600°C at 10°C/min):

The test item appearance remained stable, since a grey powder was observed after the experiment. No melting point of the test item was recorded.

Assay No. 2 (isotherm at 25°C for 5 min, heating ramp: 25°C to 600°C at 10°C/min):

The test item appearance remained stable, since a grey powder was observed after the experiment. No melting point of the test item was recorded.

Conclusions:
The melting behaviour of lutetium oxide silicate was assessed according to the EU A.1 method and OECD test guideline 102 in compliance with GLP using Differential Scanning Calorimetry (DSC). No melting point of the test item was recorded up to 600°C during the experiment.

Description of key information

In a GLP experiment assigned as key study (Klimisch 1, Demangel, 2017c) and performed according to the EU A.1 method and OECD test guideline 102, no melting point of the test item was recorded up to 600°C, using Differential Scanning Calorimetry. No decomposition was observed either. The melting point is considered to be > 600°C.