Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Description of key information

Based on the results of this study, an indication of the classification for C10-C14 alkyl ether is as follows: not classified as irritating to eyes.

Key value for chemical safety assessment

Skin irritation / corrosion

Link to relevant study records
Reference
Endpoint:
skin irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
08 to 16 December 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 439 (In Vitro Skin Irritation: Reconstructed Human Epidermis Test Method)
Deviations:
not specified
GLP compliance:
yes
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: KYOEISHA CHEMICAL CO., LTD. 7080101
- Expiration date of the lot/batch: 1/08/2019
- Purity test date:

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: Room temperature away from heat or light
- Stability under test conditions:
- Solubility and stability of the test substance in the solvent/vehicle:
- Reactivity of the test substance with the solvent/vehicle of the cell culture medium:

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing:
- Preliminary purification step (if any):
- Final dilution of a dissolved solid, stock liquid or gel:
- Final preparation of a solid:

FORM AS APPLIED IN THE TEST (if different from that of starting material)

TYPE OF BIOCIDE/PESTICIDE FORMULATION (if applicable)

OTHER SPECIFICS:
Test system:
other: SkinEthic RHE Model
Source species:
human
Cell type:
non-transformed keratinocytes
Cell source:
other: Not specified
Source strain:
other:
Vehicle:
not specified
Details on test system:
SKIN DISC PREPARATION
- Procedure used: RHE tissues were cleaned to remove basal agarose using kim wipes and then transferred to 6-well plates containing 1 mL fresh growth medium. Tissues were pre-incubated overnight, 37±1 °C in 5±1% CO2 in a 95% humidified incubator.
- Quality control for skin discs: Electrical resistance obtained with two of the isolated skin discs was [complete, e.g. 10 kΩ]
TEMPERATURE USED FOR TEST SYSTEM
- Temperature used during treatment / exposure: Room Temperature
- Temperature of post-treatment incubation (if applicable):
REMOVAL OF TEST MATERIAL AND CONTROLS
- Number of washing steps: 25
- Observable damage in the tissue due to washing:
- Modifications to validated SOP:
DYE BINDING METHOD
- Dye used in the dye-binding assay: MTT
- Spectrophotometer:
- Wavelength:
- Filter:
- Filter bandwidth:
NUMBER OF INDEPENDENT TESTING RUNS / EXPERIMENTS TO DERIVE FINAL PREDICTION:
PREDICTION MODEL / DECISION CRITERIA (choose relevant statement)
- The test substance is considered to be corrosive to skin if [complete, e.g. if the mean TER value is less than or equal to 5 kΩ and the skin disk is obviously damaged, or if the mean TER value is less than or equal to 5 kΩ, and the skin disc is showing no obvious damage, but the mean disc dye content is greater than or equal to the mean disc dye content of the 10M HCl positive control obtained concurrently.]
- The test substance is considered to be non-corrosive to skin if [complete, e.g. if the mean TER value obtained for the test substance is greater than 5 kΩ, or if the mean TER value is less than or equal to 5 kΩ, and the skin disc is showing no obvious damage, and the mean disc dye content is well below the mean disc dye content of the 10M HCl positive control obtained concurrently.]
- Justification for the selection of the cut-off point(s) if different than recommended in TG 430:
Amount/concentration applied:
TEST MATERIAL
- Amount(s) applied (volume or weight with unit): 16uL
- Concentration (if solution):

VEHICLE
- Amount(s) applied (volume or weight with unit):
- Concentration (if solution):
- Lot/batch no. (if required):
- Purity:

NEGATIVE CONTROL
- Amount(s) applied (volume or weight): 16uL
- Concentration (if solution): 5%

POSITIVE CONTROL
- Amount(s) applied (volume or weight): 16uL
- Concentration (if solution):
Duration of treatment / exposure:
42 minutes
Duration of post-treatment incubation (if applicable):
42 hours
Irritation / corrosion parameter:
% tissue viability
Value:
79.1
Remarks on result:
no indication of irritation
Interpretation of results:
GHS criteria not met
Conclusions:
Based on the results of this study, C10-C14 alkyl ether is classified as “No Category (Non Irritant)” as per “United Nations Globally Harmonized System of Classification and Labelling of Chemicals”.
Endpoint conclusion
Endpoint conclusion:
no adverse effect observed (not irritating)

Eye irritation

Link to relevant study records
Reference
Endpoint:
eye irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
30 December 2017 to 03 January 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 437 (Bovine Corneal Opacity and Permeability Test Method for Identifying Ocular Corrosives and Severe Irritants)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU method B.47 (Bovine corneal opacity and permeability test method for identifying ocular corrosives and severe irritants)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material:
Kyoeisha chemical co., Bx 7080101
- Expiration date of the lot/batch: August 01, 2019
- Purity test date: no data

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: Room temperature (Ambient), Container was kept tightly closed and away from heat or sunlight
- Stability under test conditions: no data
- Solubility and stability of the test substance in the solvent/vehicle: - Reactivity of the test substance with the solvent/vehicle of the cell culture medium:
Species:
rat
Strain:
Wistar
Details on test animals or tissues and environmental conditions:
SOURCE OF COLLECTED EYES
- Source: Deonar Abattoir slaughter house, Mumbai, Maharashtra
- Number of animals: no data
- Characteristics of donor animals (e.g. age, sex, weight): Between 1 to 5 years (age of the animals was determined based on the teeth count and horn ring count along with Horizontal Diameter of Corneas and Central Corneal Thickness)
- Storage, temperature and transport conditions of ocular tissue (e.g. transport time, transport media and temperature, and other conditions): Transported (in a sealed plastic container) under cold condition in Hanks’ Balanced Salt Solution containing antibiotics [e.g., penicillin at 100 IU/mL and streptomycin at 100 μg/mL]
- Time interval prior to initiating testing: The eyes were used within 24 hours from slaughter.
- indication of any existing defects or lesions in ocular tissue samples: Eyes were examined prior to use. Corneas from eyes free of visible defects were used. Corneas that have opacity lesser than seven opacity units or equivalent for the opacitometer were used in the study.
- Indication of any antibiotics used: Transported (in a sealed plastic container) under cold condition in Hanks’ Balanced Salt Solution containing antibiotics [e.g., penicillin at 100 IU/mL and streptomycin at 100 μg/mL]
Vehicle:
not specified
Controls:
yes, concurrent positive control
Amount / concentration applied:
TEST MATERIAL
- Amount(s) applied (volume or weight with unit):
- Concentration (if solution): 1% aqueous solution in distilled water at room temperature

VEHICLE
- Amount(s) applied (volume or weight with unit): none
- Concentration (if solution):
- Lot/batch no. (if required):
- Purity:
Duration of treatment / exposure:
Corneas were exposed for approximately 10 minutes ± 30 seconds at 32 ± 1°C.
Duration of post- treatment incubation (in vitro):
2 hours ± 10 minutes at 32 ± 1ºC.
Number of animals or in vitro replicates:
12
Details on study design:
SELECTION AND PREPARATION OF CORNEAS ; The eyes were used within 24 hours from slaughter. Eyes were examined prior to use. Corneas from eyes free of visible defects were used. Corneas that have opacity lesser than seven opacity units or equivalent for the opacitometer were used in the study.

QUALITY CHECK OF THE ISOLATED CORNEAS ; Selected corneas were mounted on the corneal holders with the endothelial side against the O-ring of the posterior half of the holder. The anterior half of the holder was then placed on the top of the cornea and fixed in place. Both chambers were then filled to excess with pre-warmed phenol red free Eagle's Minimum Essential Medium (EMEM) (posterior chamber first to return the cornea to its natural concave position), ensuring no bubbles were present within the holders. The device was then equilibrated at 32 ± 1°C for at least one hour to allow the corneas to equilibrate with the medium and to achieve normal metabolic activity, to the extent possible.

NUMBER OF REPLICATES ; 3

NEGATIVE CONTROL USED ; yes

SOLVENT CONTROL USED (if applicable)

POSITIVE CONTROL USED ; yes

APPLICATION DOSE AND EXPOSURE TIME ; 750 μL 10 minutes ± 30 seconds at 32 ± 1 °C.

TREATMENT METHOD: closed chamber

POST-INCUBATION PERIOD: yes. 2 hours ± 10 minutes at 32 ± 1ºC.

REMOVAL OF TEST SUBSTANCE
- Number of washing steps after exposure period: one
- POST-EXPOSURE INCUBATION: 2 hours ± 10 minutes at 32 ± 1ºC.

METHODS FOR MEASURED ENDPOINTS:
- Corneal opacity: Corneal opacity is measured quantitatively, as the amount of light transmission through the cornea.
- Corneal permeability: Permeability is measured quantitatively as the amount of sodium fluorescein dye that passes across the full thickness of the cornea, as detected in the medium in the posterior chamber. The test item is applied to the epithelial surface of the cornea by addition to the anterior chamber of the corneal holder.
- Others (e.g, pertinent visual observations, histopathology): (please specify)

SCORING SYSTEM: In Vitro Irritancy Score (IVIS) IVIS = mean opacity value + (15 x mean permeability OD490 value)

DECISION CRITERIA: please specify if the decision criteria as indicated in the TG was used.
Irritation parameter:
in vitro irritation score
Run / experiment:
17
Value:
1.03
Vehicle controls validity:
valid
Negative controls validity:
valid
Positive controls validity:
valid
Irritation parameter:
in vitro irritation score
Run / experiment:
23
Value:
-0.77
Vehicle controls validity:
valid
Negative controls validity:
valid
Positive controls validity:
valid
Irritation parameter:
in vitro irritation score
Run / experiment:
25
Value:
2.89
Vehicle controls validity:
valid
Negative controls validity:
valid
Positive controls validity:
valid
Irritation parameter:
cornea opacity score
Run / experiment:
17
Value:
1.58
Vehicle controls validity:
valid
Negative controls validity:
valid
Positive controls validity:
valid
Irritation parameter:
cornea opacity score
Run / experiment:
23
Value:
-0.95
Vehicle controls validity:
valid
Negative controls validity:
valid
Positive controls validity:
valid
Irritation parameter:
cornea opacity score
Run / experiment:
25
Value:
2.38
Vehicle controls validity:
valid
Negative controls validity:
valid
Positive controls validity:
valid
Interpretation of results:
GHS criteria not met
Conclusions:
The mean IVIS score for the corneas treated with C10-C14 alkyl ether was found to be 1.05. Based on the results of this study, an indication of the classification for C10-C14 alkyl ether is as follows: not classified as irritating to eyes.
Endpoint conclusion
Endpoint conclusion:
no adverse effect observed (not irritating)

Respiratory irritation

Endpoint conclusion
Endpoint conclusion:
no study available

Additional information

Justification for classification or non-classification

The mean IVIS score for the corneas treated with C10-C14 alkyl ether was found to be 1.05. Based on the results of this study, an indication of the classification for C10-C14 alkyl ether is as follows: not classified as irritating to eyes.