Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
10th October 2016 to 05th September 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.2 (Boiling Temperature)
Qualifier:
according to guideline
Guideline:
OECD Guideline 103 (Boiling Point)
GLP compliance:
yes (incl. QA statement)
Type of method:
method according to Siwoloboff

Test material

Constituent 1
Reference substance name:
Undecanolactone
EC Number:
254-399-3
EC Name:
Undecanolactone
Cas Number:
39282-36-5
Molecular formula:
C11H20O2
IUPAC Name:
(5E,13E)-icosa-5,13-dienoic acid; 6-tetradecyloxan-2-one
Specific details on test material used for the study:
Identity: RM1004952
Appearance: Off-white, soft solid
Storage conditions: Room temperature (15 to 25°C)
Batch number: 1383Q12001
Purity: 100%
Expiry date: 30 August 2017
Date received: 05 October 2015

Results and discussion

Boiling point
Key result
Boiling pt.:
< 169 °C
Atm. press.:
>= 1 021 - <= 1 026 mBar
Decomposition:
yes
Decomp. temp.:
ca. 168 °C
Remarks on result:
not determinable

Applicant's summary and conclusion

Conclusions:
The substance's boiling point was not determinable due to substance decomposition at 168 °C without boiling at 1021 - 1026 mbar.
Executive summary:

The substance's boiling point was studied in accordance with EU Method A.2 and OECD Guideline 103 via a GLP-certified laboratory. Using the Siwoloboff method the boiling point was not determinable due to substance decomposition at 168 °C without boiling at 1021 - 1026 mbar.