Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
in vitro gene mutation study in bacteria
Type of information:
experimental study
Adequacy of study:
key study
Study period:
25th August 2011 to 14th November 2011
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report date:
2011

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 471 (Bacterial Reverse Mutation Assay)
Qualifier:
according to guideline
Guideline:
EU Method B.13/14 (Mutagenicity - Reverse Mutation Test Using Bacteria)
GLP compliance:
yes
Type of assay:
bacterial reverse mutation assay

Test material

Constituent 1
Chemical structure
Reference substance name:
3-chloro-4-fluoroaniline
EC Number:
206-682-8
EC Name:
3-chloro-4-fluoroaniline
Cas Number:
367-21-5
Molecular formula:
C6H5ClFN
IUPAC Name:
3-chloro-4-fluoroaniline

Method

Species / strain
Species / strain / cell type:
S. typhimurium TA 1535, TA 1537, TA 98, TA 100 and E. coli WP2
Metabolic activation:
with and without
Metabolic activation system:
Metabolic activation system
Rat liver microsomal enzymes (S9 homogenate) was obtained from Trinova Biochem GmbH, Giessen, Germany and was prepared from male Sprague Dawley rats that had been injected intraperitoneal with Aroclor (500 mg/kg).
Preparation of S9-mix
S9-mix was prepared immediately before use and kept on ice. S9-mix contained per 10 ml: 30 mg NADP (Randox Laboratories Ltd., Crumlin, United Kingdom) and 15.2 mg glucose-6-phosphate (Roche Diagnostics, Mannheim, Germany) in 5.5 ml or 5.0 ml Milli-Q water (first or second experiment respectively) (Millipore Corp., Bedford, MA., USA); 2 ml 0.5 M sodium phosphate buffer pH 7.4; 1 ml 0.08 M MgCl2 solution (Merck); 1 ml 0.33 M KCl solution (Merck). The above solution was filter (0.22 μm)-sterilized. To 9.5 ml of S9-mix components 0.5 ml S9-fraction was added (5% (v/v) S9-fraction) to complete the S9-mix in the first experiment and to 9.0 ml of S9- ix components 1.0 ml S9-fraction was added (10% (v/v) S9-fraction) to complete the S9-mix in the second experiment. The S9-batch used was no. 2732.
Test concentrations with justification for top dose:
Selection of an adequate range of doses was based on a dose range finding test with the strains TA100 and WP2uvrA, both with and without 5% (v/v) S9-mix. Eight concentrations, 3, 10, 33, 100, 333, 1000, 3330 and 5000 μg/plate were tested in triplicate. This dose range finding test was reported as a part of the first experiment of the mutation assay. The highest concentration of PF- 1458762 used in the subsequent mutation assay was 5000 μg/plate or the level at which the test substance inhibited bacterial growth.
Vehicle / solvent:
DMSO = dimethyl sulfoxide (Merck)
Controlsopen allclose all
Untreated negative controls:
yes
Negative solvent / vehicle controls:
yes
Remarks:
DMSO (dimethyl sulfoxide)
Positive controls:
yes
Positive control substance:
other: 2-aminoanthracene
Untreated negative controls:
yes
Negative solvent / vehicle controls:
yes
Remarks:
DMSO (dimethyl sulfoxide)
Positive controls:
yes
Positive control substance:
4-nitroquinoline-N-oxide
2-nitrofluorene
sodium azide
methylmethanesulfonate
other: ICR-191
Details on test system and experimental conditions:
Mutation assay
At least five different doses (increasing with approximately half-log steps) of the test substance were tested in triplicate in each strain. In the first experiment PF-01458762 was tested both in the absence and presence of 5% (v/v) S9-mix in tester strains TA1535, TA1537, and TA98. In an independent repeat of the assay with additional parameters, the test substance was tested both in the absence and presence of 10% (v/v) S9-mix in all tester strains. An additional experiment was performed with tester strain WP2uvrA in the absence and presence of S9-mix.
The negative control (vehicle) and relevant positive controls were concurrently tested in each strain in the presence and absence of S9-mix.
Top agar in top agar tubes was melted by heating to 45°C. The following solutions were successively added to 3 ml molten top agar: 0.1 ml of a fresh bacterial culture (109 cells/ml) of one of the tester strains, 0.1 ml of a dilution of the test substance in dimethyl sulfoxide and either 0.5 ml S9-mix (in case of activation assays) or 0.5 ml 0.1 M phosphate buffer (in case of non- activation assays). The ingredients were mixed on a Vortex and the content of the top agar tube was poured onto a selective agar plate. After solidification of the top agar, the plates were inverted and incubated in the dark at 37.0 ± 1.0 °C for 48 ± 4 h. After this period revertant colonies histidine independent (His+) for Salmonella typhimurium bacteria and tryptophan independent (Trp+) for Escherichia coli were counted.

Colony counting
The revertant colonies (histidine independent or tryptophan independent) were counted manually if less than 40 colonies per plate were present. If more than 40 colonies were present, these were counted automatically with a Biocount 4000 Pro-S-colony counter. Plates with abundant test substance precipitate which interfered with automated colony counting were counted manually and the evidence of test substance precipitate on the plates was recorded. The condition of the bacterial background lawn was evaluated, both macroscopically and microscopically by using a dissecting microscope.
Evaluation criteria:
A test substance is considered negative (not mutagenic) in the test if:
a) The total number of revertants in tester strain TA100 is not greater than two (2) times the concurrent control, and the total number of revertants in tester strains TA1535, TA1537, TA98 or WP2uvrA is not greater than three (3) times the concurrent vehicle control.
b) The negative response should be reproducible in at least one independently repeated experiment.

A test substance is considered positive (mutagenic) in the test if:
a) The total number of revertants in tester strain TA100 is greater than two (2) times the concurrent control, or the total number of revertants in tester strains TA1535, TA1537, TA98 or WP2uvrA is greater than three (3) times the concurrent vehicle control.
b) In case a repeat experiment is performed when a positive response is observed in one of the tester strains, the positive response should be reproducible in at least one independently repeated experiment.

Results and discussion

Test resultsopen allclose all
Key result
Species / strain:
S. typhimurium TA 98
Metabolic activation:
with and without
Genotoxicity:
negative
Cytotoxicity / choice of top concentrations:
cytotoxicity
Remarks:
concentration range of 100 to 5000 μg/plate
Vehicle controls validity:
valid
Untreated negative controls validity:
valid
Positive controls validity:
valid
Key result
Species / strain:
S. typhimurium TA 100
Metabolic activation:
with and without
Genotoxicity:
negative
Cytotoxicity / choice of top concentrations:
cytotoxicity
Remarks:
concentrations of 100 to 5000 μg/plate
Vehicle controls validity:
valid
Untreated negative controls validity:
valid
Positive controls validity:
valid
Key result
Species / strain:
S. typhimurium TA 1535
Metabolic activation:
with and without
Genotoxicity:
negative
Cytotoxicity / choice of top concentrations:
cytotoxicity
Remarks:
concentration range of 100 to 5000 μg/plate
Vehicle controls validity:
valid
Untreated negative controls validity:
valid
Positive controls validity:
valid
Key result
Species / strain:
S. typhimurium TA 1537
Metabolic activation:
with and without
Genotoxicity:
negative
Cytotoxicity / choice of top concentrations:
cytotoxicity
Remarks:
100 to 5000 μg/plate
Vehicle controls validity:
valid
Untreated negative controls validity:
valid
Positive controls validity:
valid
Key result
Species / strain:
E. coli WP2 uvr A
Metabolic activation:
with and without
Genotoxicity:
negative
Cytotoxicity / choice of top concentrations:
no cytotoxicity
Vehicle controls validity:
valid
Untreated negative controls validity:
valid
Positive controls validity:
valid

Applicant's summary and conclusion

Conclusions:
Based on the results of this study it is concluded that PF-01458762 is not mutagenic in the Salmonella typhimurium reverse mutation assay and in the Escherichia coli reverse mutation assay.
Executive summary:

Evaluation of the mutagenic activity of PF-01458762 in the Salmonella typhimurium reverse mutation assay and the Escherichia coli reverse mutation assay (with independent repeat).
PF-01458762 was tested in the Salmonella typhimurium reverse mutation assay with four histidine requiring strains of Salmonella typhimurium (TA1535, TA1537, TA98 and TA100) and in the Escherichia coli reverse mutation assay with a tryptophan-requiring strain of Escherichia coli (WP2uvrA). The test was performed in two independent experiments in the presence and absence of S9-mix (rat liver S9-mix induced by Aroclor). To obtain more information about the possible mutagenicity of PF-01458762, an additional experiment was performed with tester strain WP2uvrA.
The study procedures described in this report were based on the most recent OECD and EC guidelines.
Batch E010012175 of PF-01458762 consisted of white crystal lumps with a purity of 99.5%. The test substance was dissolved in dimethyl sulfoxide.
In the dose range finding test, PF-01458762 was tested up to concentrations of 5000 μg/plate in the absence and presence of S9-mix in the strains TA100 and WP2uvrA. PF-01458762 did not precipitate on the plates at this dose level. Toxicity was observed at test substance concentrations of 3330 and 5000 μg/plate in tester strain TA100 and at 1000 μg/plate in tester strain WP2uvrA both in the absence and presence of S9-mix. Results of this dose range finding test were reported as part of the first experiment of the mutation assay.
Based on the results of the dose range finding test, PF-01458762 was tested in the first mutation assay at a concentration range of 100 to 5000 μg/plate in the absence and presence of 5% (v/v) S9-mix in tester strains TA1535, TA1537 and TA98. Toxicity was observed in the tester strains
TA1537 and TA98 in the absence of S9-mix only.
In an independent repeat of the assay with additional parameters, PF-01458762 was tested at a concentration range of 100 to 5000 μg/plate in the absence and presence of 10% (v/v) S9-mix in the tester strains TA1535, TA1537, TA98 and TA100 and at 33 to 3330 μg/plate in the absence and presence of 10% (v/v) S9-mix in tester strain WP2uvrA. Toxicity was observed in all tester strains in the absence and presence of S9-mix, except in tester strain TA98 (presence of S9-mix) and WP2uvrA (absence and presence of S9-mix).
Since in tester strain WP2uvrA in the second experiment no toxicity or precipitate on the plates was observed, a third mutation experiment was performed with this strain at a concentration range of 333 to 5000 μg/plate in the absence and presence of 10% (v/v) S9-mix.
PF-01458762 did not induce a significant dose-related increase in the number of revertant (His+) colonies in each of the four tester strains (TA1535, TA1537, TA98 and TA100) and in the number of revertant (Trp+) colonies in tester strain WP2uvrA both in the absence and presence of S9-metabolic activation. These results were confirmed in independently repeated experiments.
In this study, the negative and strain-specific positive control values were within the laboratory historical control data ranges indicating that the test conditions were adequate and that the metabolic activation system functioned properly.
Based on the results of this study it is concluded that PF-01458762 is not mutagenic in the Salmonella typhimurium reverse mutation assay and in the Escherichia coli reverse mutation assay.