Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Experimental starting date: 26 October 2017 Experimental completion date: 07 March 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC method
Partition coefficient type:
octanol-water

Test material

Constituent 1
Chemical structure
Reference substance name:
Ethylene bis[1,3-dihydro-1,3-dioxoisobenzofuran-5-carboxylate]
EC Number:
217-062-1
EC Name:
Ethylene bis[1,3-dihydro-1,3-dioxoisobenzofuran-5-carboxylate]
Cas Number:
1732-96-3
Molecular formula:
C20H10O10
IUPAC Name:
2-(1,3-dioxo-1,3-dihydro-2-benzofuran-5-carbonyloxy)ethyl 1,3-dioxo-1,3-dihydro-2-benzofuran-5-carboxylate
impurity 1
Chemical structure
Reference substance name:
Benzene-1,2,4-tricarboxylic acid 1,2-anhydride
EC Number:
209-008-0
EC Name:
Benzene-1,2,4-tricarboxylic acid 1,2-anhydride
Cas Number:
552-30-7
Molecular formula:
C9H4O5
IUPAC Name:
Benzene-1,2,4-tricarboxylic acid 1,2-anhydride
impurity 2
Chemical structure
Reference substance name:
not assignable
IUPAC Name:
not assignable
Specific details on test material used for the study:
Identification: RIKACID TMEG-500
CAS No.: 1732-96-3
Chemical name: Ethylene bis[1,3-dihydro-1,3-dioxoisobenzofuran-5-carboxylate]
Appearance/physical state: cream colored powder
Batch: 5259
Purity: 81.1%
Expiry date: 24 April 2018
Storage conditions: room temperature, in the dark

Study design

Analytical method:
high-performance liquid chromatography

Results and discussion

Partition coefficient
Type:
log Pow
Partition coefficient:
3.33
Temp.:
30 °C
pH:
1.5
Details on results:
Preliminary Estimate
The log10 Pow was calculated to be 3.47.

Definitive Test Calibration
Mean log10 Pow: 3.33
Partition coefficient: 2.11 x 10^3





Any other information on results incl. tables

Calibration

 

The retention times of the dead time and the retention times, capacity factors (k') and log10 Powvalues for the reference standards are shown in the following tables. 

Dead time

Retention Time (mins)

Mean Retention Time (mins)

Injection 1

Injection 2

Thiourea

1.273

1.273

1.273

 

Standard

Retention Time (mins)

Capacity Factor (k')

Log10k'

Log10Pow

Injection 1

Injection 2

Mean

2-Butanone

1.691

1.696

1.693

0.330

-0.481

0.3

Benzyl alcohol

1.808

1.808

1.808

0.420

-0.377

1.1

Benzene

4.417

4.417

4.417

2.469

0.393

2.1

Toluene

6.788

6.788

6.788

4.332

0.637

2.7

Naphthalene

10.160

10.165

10.163

6.983

0.844

3.6

Phenanthrene

24.553

24.553

24.553

18.286

1.262

4.5

 

Partition coefficient of sample

 

The retention times, capacity factor and log10Powvalue determined for the sample are shown in the following table:

Injection

Retention Time (mins)

Capacity Factor (k')

Log10k'

Log10Pow

1

9.106

6.153

0.789

3.33

2

9.106

6.153

0.789

3.33

Mean log10Pow: 3.33
Partition coefficient:  2.11 x 103

 Discussion

Although the parent test item contained no dissociating functional groups, the mobile phase was strongly acidified in order to minimize hydrolysis of the test item’s acid anhydride functional groups, which is typically a base catalyzed reaction. Despite this precautionary step, reactivity of the test item within the mobile phase remained evident. In addition to the major peak eluting at approximately 9 minutes, which was attributed to the parent test item and used for quantification of the partition coefficient, further, earlier eluting, more hydrophilic peaks were observed, which were attributed to the hydrolysis products of the test item.

During development of the analytical method for the determination, on preparation of a test item sample solution in mobile phase, as opposed to acetonitrile, only proposed hydrolysis product peaks were observed on analysis. This fully supported the instability of the test item in even a strongly acidified mobile phase. 

 

Applicant's summary and conclusion

Conclusions:
The partition coefficient of the test item has been determined to be 2.11 x 10^3, log10 Pow 3.33.
Executive summary:

Partition Coefficient (n-Octanol/water). 2.11 x 103, log10Pow 3.33, determined using an HPLC method designed to be compatible with Method A.8 Partition Coefficient of Commission Regulation (EC) No 440/2008 of 30 May 2008andMethod 117 of the OECD Guidelines for Testing of Chemicals, 13 April 2004.