Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1992

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Version / remarks:
92/69/EEC, A3 Air comparison pycnometer method
Deviations:
yes
Remarks:
The temperature during the measurement was 22°C instead of 20°C
GLP compliance:
yes
Type of method:
air comparison pycnometer (for solids)

Test material

Constituent 1
Chemical structure
Reference substance name:
1,10-bis(2,2,6,6-tetramethyl-1-piperidinyloxy)-1,10-dioxodecane
EC Number:
417-440-8
EC Name:
1,10-bis(2,2,6,6-tetramethyl-1-piperidinyloxy)-1,10-dioxodecane
Cas Number:
2516-92-9
Molecular formula:
C28 H50 N2 O6
IUPAC Name:
bis(1-hydroxy-2,2,6,6-tetramethylpiperidin-4-yl) decanedioate
Details on test material:
Identification code (lab) = TKA 40075

Results and discussion

Density
Type:
relative density
Density:
1.12
Temp.:
22 °C

Applicant's summary and conclusion

Conclusions:
Relative density according to EU Method A.3: 1.12