Physical & Chemical properties

Water solubility

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Study period:
16 February 2017 to 03 March 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 105 (Water Solubility)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.6 (Water Solubility)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
flask method
Key result
Water solubility:
0.015 g/L
Conc. based on:
test mat.
Loading of aqueous phase:
0.1 g/L
Incubation duration:
>= 24 - <= 72 h
Temp.:
20 °C
pH:
>= 5.5 - <= 5.6
Details on results:
PRELIMINARY TEST
- The preliminary estimate of water solubility using a loading rate of 0.1 g/L was 1.15 x 10E-03 gTOC/L at 20.0 ± 0.5 °C and pH 5.7.
- The preliminary estimate of water solubility using a loading rate of 1 g/L was 4.91 x 10E-03 gTOC/L at 20.0 ± 0.5 °C and pH 5.8.
- The preliminary estimate of water solubility using a loading rate of 10 g/L was 2.20 x 10E-02 gTOC/L at 20.0 ± 0.5 °C and pH 5.3.

DEFINITIVE TEST
- The analysed concentrations of total organic carbon (TOC) obtained from the sample solutions and blanks are shown in Table 16 (below).
- Concentration (g/L) of TOC in the sample solutions at 20.0 ± 0.5 °C are shown in Table 17 (below).

TABLE 16 – ANALYSED TOC CONCENTRATIONS IN THE MAIN TEST

Sample

Concentration (mgTOC/L)

Matrix blank A

0.3069

Matrix blank B

0.2923

Sample 1A

1.416

Sample 1B

1.538

Sample 2A

1.592

Sample 2B

1.570

Sample 3A

1.285

Sample 3B

1.281

 

TABLE 17– CONCENTRATION OF TOC IN SAMPLE SOLUTIONS

Sample number

Concentration (gTOC/L)

Solution pH

1

1.48 x 10-3

5.5

2

1.58 x 10-3

5.6

3

1.28 x 10-3

5.6

Mean result: 1.45 x 10E-03 gTOC/L at 20.0 ± 0.5 °C

Conclusions:
Water solubility of the test item was determined by total organic carbon analysis to be 1.45 x 10E-03 gTOC/L of solution at 20.0 ± 0.5 °C. The result was based on a nominal loading rate of 0.1 g/L.
Executive summary:

GUIDELINE

The determination was carried out using the flask method, designed to be compatible with Method A.6 Water Solubility of Commission Regulation (EC) No 440/2008 of 30 May 2008 and Method 105 of the OECD Guidelines for Testing of Chemicals, 27 July 1995.

 

RESULTS

Water solubility of the test item was determinedby total organic carbonto be 1.45 x 10E-03 gTOC/L of solution at 20.0 ± 0.5 °C. The result was based on a nominal loading rate of 0.1 g/L.

Description of key information

Water solubility of the test item was determined by total organic carbon analysis to be 1.45 x 10E-03 gTOC/L of solution at 20.0 ± 0.5 °C. The result was based on a nominal loading rate of 0.1 g/L (OECD 105 and EU Method A.6).

Key value for chemical safety assessment

Water solubility:
0.001 g/L
at the temperature of:
20 °C

Additional information

GUIDELINE

The determination was carried out using the flask method, designed to be compatible with Method A.6 Water Solubility of Commission Regulation (EC) No 440/2008 of 30 May 2008 and Method 105 of the OECD Guidelines for Testing of Chemicals, 27 July 1995.

 

RESULTS

Water solubility of the test item was determined by total organic carbon analysis to be 1.45 x 10E-03 gTOC/L of solution at 20.0 ± 0.5 °C. The result was based on a nominal loading rate of 0.1 g/L.