Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
25 April 2016 to 26 April 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus
Key result
Remarks on result:
no flash point according to standard method
Remarks:
no flash point below 300 °C

RESULTS

- Results of the flash point determination are shown in Table 1 (below).

 

TABLE 1 – RESULTS OF FLASH POINT DETERMINATION

Test temperature (°C)

Observations

25.0

No flash

30.0

No flash

35.0

No flash

40.0

No flash

45.0

No flash

50.0

No flash

55.0

No flash

60.0

No flash

65.0

No flash

70.0

No flash

75.0

No flash

80.0

No flash

85.0

No flash

90.0

No flash

95.0

No flash

100.0 (fresh sample)

No flash

105.0

No flash

110.0

No flash

115.0

No flash

120.0

No flash

125.0

No flash

130.0

No flash

135.0

No flash

140.0

No flash

145.0

No flash

150.0

No flash

150.0 (fresh sample)

No flash

155.0

No flash

160.0

No flash

165.0

No flash

170.0

No flash

175.0

No flash

180.0

No flash

185.0

No flash

190.0

No flash

195.0

No flash

200.0

No flash

200.0 (fresh sample)

No flash

205.0

No flash

210.0

No flash

215.0

No flash

220.0

No flash

225.0

No flash

230.0

No flash

235.0

No flash

240.0

No flash

245.0

No flash

250.0

No flash

250.0 (fresh sample)

No flash

255.0

No flash

260.0

No flash

265.0

No flash

270.0

No flash

275.0

No flash

280.0

No flash

285.0

No flash. The flame self-extinguished.

290.0

No flash. The flame self-extinguished.

295.0

No flash

300.0

No flash. The flame self-extinguished.

300.0 (fresh sample)

No flash

Atmospheric pressure: Not reported

Interpretation of results:
GHS criteria not met
Conclusions:
The test item was determined not to have a flash point below 300 °C.
Executive summary:

GUIDELINE

The determination was carried out using a closed cup Setaflash 30000-0 flash point tester and was designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008.

 

RESULTS

The test item was determined not to have a flash point below 300 °C.

Description of key information

The test item was determined not to have a flash point below 300 °C (EU Method A.9).

Key value for chemical safety assessment

Additional information

GUIDELINE

The determination was carried out using a closed cup Setaflash 30000-0 flash point tester and was designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008.

 

RESULTS

The test item was determined not to have a flash point below 300 °C.