Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Hydrolysis

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
hydrolysis
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is readily biodegradable
Justification for type of information:
In accordance with Column 2 of REACH Annex VIII, information requirement section 9.2.2.1, this study does not need to be conducted if the substance is readily biodegradable. The test material contains no nitrogen therefore the evaluation of biodegradation has to be based ThODNH4. The criterion for ready biodegradability under the conditions of a manometric respirometry test is the 10-day window, describing the period between reaching at least 10 % degradation and 60 % degradation. The mean biodegradation after 28 days of the test material was 85 % (ThODNH4); the 10-day window criterion was passed from day 8 to day 18. Test data have therefore shown that the test material is readily biodegradable and as such testing is not required.

Description of key information

In accordance with Column 2 of REACH Annex VIII, information requirement section 9.2.2.1, this study does not need to be conducted if the substance is readily biodegradable. The test material contains no nitrogen therefore the evaluation of biodegradation has to be based ThODNH4. The criterion for ready biodegradability under the conditions of a manometric respirometry test is the 10-day window, describing the period between reaching at least 10 % degradation and 60 % degradation. The mean biodegradation after 28 days of the test material was 85 % (ThODNH4); the 10-day window criterion was passed from day 8 to day 18. Test data have therefore shown that the test material is readily biodegradable and as such testing is not required.

Key value for chemical safety assessment

Additional information