Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes
Specific details on test material used for the study:
None
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Safety Pre-Test:

A small amount of the test item was heated on a magnesia groove with a gas burner. Glowing was observed. The test item showed no signs of ignition.

Preliminary screening test:

The test item was heated with the flame of a teclu burner. Glowing was observed during heating. No ignition occurred within two minutes.

Conclusions:
FAT 21030/E TE should be considered as not highly flammable.
Executive summary:

FAT 21030/E TE was evaluated for flammability potential in a test conducted in accordance to EU Method A.10 (Flammability (Solids)). During the screening test, a 250 mm pile of the test item was heated with the flame of a teclu burner. Glowing was observed during heating. No ignition occurred within two minutes. Hence, determination of burning rate was not required and the test item FAT 21030/E TE was considered as not highly flammable.

Description of key information

FAT 21030/E TE was evaluated for flammability potential in a test conducted in accordance to EU Method A.10 (Flammability (Solids)). During the screening test, a 200 mm pile of the test item was heated with the flame of a teclu burner. Glowing was observed during heating. No ignition occurred within two minutes. Hence, determination of burning rate was not required and the test item FAT 21030/E TE was considered as not highly flammable.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

FAT 21030/E TE was considered as not highly flammable, hence it does not require classification in accordance with the criteria of Regulation (EC) No. 1272/2008.