Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
January, 2019 to April, 2021
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2021
Report date:
2021

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Version / remarks:
27 July 1995
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Version / remarks:
30 May 2008
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
pour point

Test material

Constituent 1
Reference substance name:
Reaction mass of (Tetramethylcyclotetrasiloxane propylether) prop-1-enylether bisphenol A and Di(tetramethylcyclotetrasiloxane propylether) bisphenol A
Cas Number:
203874-34-4
Molecular formula:
(OSiHxCH3)4-CH2-CH2 -CH2- O-C6H4-C(CH3)2-C6H4-0-CH2-CH2-CH2-(SiHxCH3O)4
IUPAC Name:
Reaction mass of (Tetramethylcyclotetrasiloxane propylether) prop-1-enylether bisphenol A and Di(tetramethylcyclotetrasiloxane propylether) bisphenol A
Test material form:
liquid
Details on test material:
Appearance: Pale yellow liquid
Specific details on test material used for the study:
Storage conditions: Room temperature in the dark, under nitrogen.

Results and discussion

Melting / freezing point
Key result
Melting / freezing pt.:
< -20 °C
Remarks on result:
other: Pour point

Any other information on results incl. tables

As a pour point of less than -20 °C was obtained in the preliminary test, the requirement of a main test to determine a definitive value was not necessary.

Applicant's summary and conclusion

Conclusions:
The pour point of the test item has been determined to be less than -20 °C (<253 K).