First-aid measures

Emergency measure - Inhalation: Remove to fresh air. Restore breathing. Keep warm and quiet

and seek medical attention.

Emergency measure - Eyes: Flush eyes with a large amount of water for at least 15

minutes. Seek medical attention.

Emergency measure - Skin: Wash affected areas thoroughly with soap and water. Seek

medical attention if irritation persists.

Emergency measure - Ingestion: Seek immediate medical attention.

Fire-fighting measures

Recommended extinguishing agent: carbon dioxide, dry chemical or foam

Product arising from burning: The substance is combustible and will burn if involved in a

fire, evolving noxious fumes (eg carbon and nitrogen

oxides). However, there is no experimental evidence to

support the anticipated combustion products.

Product determined by test: N

Protective equipment: Full protective clothing and self-contained breathing

apparatus must be worn.

Accidental release measures

Emergency measures in case of spillage: Evacuate personnel from immediate vicinity.

Wear appropriate personal protective equipment conforming to

the relevant national or international standards as

mentioned in section 2.3.10.

Absorb spillages of solutions with a suitable inert material

(eg sand or soil). Carefully transfer the spillage to waste

containers, or use a sealed industrial vacuum machine.

Containers filled with waste material must be labelled in

the same way as the original containers.

Clean the spillage area with water and detergent.

Waste material should be recovered where possible.

Handling and storage

Handling: The substance should be stored, handled and used in

conditions of good industrial hygiene and in conformity with

any local regulations in order to avoid exposure.

Engineering controls are necessary to reduce exposure to the

substance.

When exposure cannot be prevented or adequately controlled

appropriate personal protective equipment should be worn.

Such protective equipmemt should conform to the appropriate

international or national standards as follows;

Chemical protective gloves to Standard EN374

Chemical resistant clothing to Standard EN368

Eye protection to Standard EN166

When necessary appropriate respiratory protection should be

used. e.g. an organic vapour mask conforming to EN405 FFA1.

The standards mentioned above should be regarded as a

minimum.

Storage: Store in a cool, dry, well-ventilated area.

Keep containers tightly closed when not in use.

Packaging of the substance and or preparation: 20kg plastic pail, 50kg plastic or steel drum.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport code: None
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None reported.

Chemical reaction with water: None reported.

Dust explosion: Not applicable.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Recovery from any spillages or accidental discharge of

formulations containing the substance should be encouraged

where economically or technically feasible.

The substance may be lost during the recycling of

formulations and can be subsequently disposed of by landfill

or incineration at a licensed waste disposal site.

Industry - Possibility of neutralisation: No chemical treatment is practicable to neutralise the

hazardous health properties.

Industry - Possibility of destruction: controlled discharge: The substance may be disposed of by landfill at an

authorised site in accordance with local regulations, where

possible, following recycling of formulations containing the

substance.

Industry - Possibility of destruction - incineration: The substance can be disposed of by incineration by burning

under controlled conditions at a licensed waste treatment

processor in accordance with local regulations. Stack gases

should be scrubbed, because noxious fumes (eg carbon and

nitrogen oxides) could be formed.

Industry - Possibility of destruction - water purification: The substance should not normally be discharged directly to

the sewage system or the aqueous environment.

Public at large - Possibility of recovery/recycling: Not applicable. The substance will not enter the public

domain.