Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017/6/10 - 2017/6/30
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 103 (Boiling Point)
Deviations:
no
GLP compliance:
not specified
Type of method:
method according to Siwoloboff
Remarks on result:
not determinable
Remarks:
The test item started melting at 130 ºC. The physical state of the test item was turned to viscous paste and spilled out from the sample tube. Hence, the boiling point of manganese glucoheptonate could not be determined.
Conclusions:
The test item started melting at 130 ºC. The physical state of the test item turned to viscous paste and spilled out from the sample tube. Hence, the boiling point of manganese glucoheptonate could not be determined.
Executive summary:

The boiling point / boiling range of manganese glucoheptonate was determined according to OECD Guideline 103 (Boiling Point) by Siwoloboff method.

The test item started melting at 130 ºC. The physical state of the test item was turned to viscous paste and spilled out from the sample tube. Hence, the boiling point of manganese glucoheptonate could not be determined.

Description of key information

The boiling point / boiling range of manganese glucoheptonate was determined according to OECD Guideline 103 (Boiling Point) by Siwoloboff method.

The test item started melting at 130 ºC. The physical state of the test item turned to viscous paste and spilled out from the sample tube. Hence, the boiling point of manganese glucoheptonate could not be determined.

Key value for chemical safety assessment

Additional information