First-aid measures

Emergency measure - Inhalation: Remove from exposure immediately. Use a bag valve mask or

similar device to perform artificial respiration (rescue

breathing) if needed. Get medical attention.

Emergency measure - Eyes: Wash eyes immediately with large amounts of water or normal

saline, occasionally lifting upper and lower lids, until no

evidence of chemical remains. Get medical attention

immediately.

Emergency measure - Skin: Remove contaminated clothing & shoes immediately. Wash with

soap or mild detergent and large amounts of water until no

evidence of chemical remains (at least 15-20min). Get

medical attention immediately, if needed.

Emergency measure - Ingestion: If vomiting occurs, keep head lower than hips to prevent

aspiration. Get medical attention immediately, if needed.

Fire-fighting measures

Recommended extinguishing agent: Water spray, dry chemical powder, carbon dioxide,

regular foam.

Product arising from burning: Oxides of Carbon and Nitrogen.

Product determined by test: N

Protective equipment: Use self contained breathing apparatus and full body

protective equipment.

Accidental release measures

Emergency measures in case of spillage: In the event of spillage (open handling) - evacuate

immediate area. Sweep or vacuum up and place in clean, dry

containers for disposal (incineration). Keep out of sewers &

drains.

PPE: respiratory (NIOSH approved), skin and eye protection

to prevent overexposure. (Gloves, Tyvex-Suit & Respirator

with Particle Filter)

Spill-kits, eyewash and safety showers available in all

Formyl Pyrrole handling areas.

Handling and storage

Handling: Avoid contact and inhalation of dust. Operate in areas

provided with efficient local exhaust ventilation systems.

All dispensing, sampling and charging operations to be

carried out in closed systems, i.e. using glove box and

doverpac containment technology.

Handling of Formyl Pyrrole should only be carried out using

nitrile gloves to standard EN 374, safety glasses to

standard EN 166, NIOSH approved full face mask respirator

with a silicon rubber mask to comply with EN 136 and a visor

to standard EN 166. Filter complies with standards EN

141.2000/EN 12941/EN12942.

In the event of spillage (open handling) - evacuate

immediate area. Sweep or vacuum up and place in clean, dry

containers for disposal (incineration). Keep out of sewers &

drains.

PPE: respiratory, skin and eye protection to prevent

overexposure. (Nitrile gloves to standard EN 374, Tyvek-suit

& fullface mask respirator.)

Spill-kits, eyewash and safety showers available in all

Formyl Pyrrole handling areas.

Storage: Store in tightly closed containers, in a cool dry, well

ventilated area.

The product is incompatible with bases and oxidizing

materials.

Keep away from oxidizing substances.

Packaging of the substance and or preparation: The test substance should be packaged in a 500mm x 850mm

double polyethylene liner (e.g., a bag within              a

bag) inside a sealed (e.g., lever lock lid) 31 L UN fiber

drum. The material can be shipped under ambient conditions.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Chemical reaction with water: Will not react with water.

Dust explosion: Dust/Air mixtures may ignite/explode.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Not applicable.

Industry - Possibility of neutralisation: Not applicable.

Industry - Possibility of destruction: controlled discharge: Not applicable.

Industry - Possibility of destruction - incineration: All waste to be sent off site for incineration.

Industry - Possibility of destruction - water purification: Not applicable.

Industry - Possibility of destruction - other: Not applicable.

Public at large - Possibility of recovery/recycling: Not applicable.

Public at large - Possibility of neutralisation: Not applicable.

Public at large - Possibility of destruction: controlled discharge: Not applicable.

Public at large - Possibility of destruction - incineration: Not applicable.

Public at large - Possibility of destruction - water purification: Not applicable.

Public at large - Possibility of destruction - others: Not applicable.