Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
3 (not reliable)
Rationale for reliability incl. deficiencies:
other: company data only

Data source

Reference
Reference Type:
other: company data
Title:
Unnamed
Year:
2014

Materials and methods

Test guideline
Qualifier:
no guideline available
Principles of method if other than guideline:
Cleveland Open Cup Tester
GLP compliance:
no
Type of method:
open cup
Remarks:
Cleveland Open Cup Tester

Test material

Constituent 1
Reference substance name:
Allyl nonylphenol
IUPAC Name:
Allyl nonylphenol
Test material form:
gas under pressure: refrigerated liquefied gas

Results and discussion

Flash point
Flash point:
ca. 150 °C
Atm. press.:
ca. 1 013 hPa

Applicant's summary and conclusion

Conclusions:
Flash Point was measured by cleveland open cup tester. The value is 150 °C.
Executive summary:

Flash Point was measured by cleveland open cup tester. The value is 150 °C.