Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Adsorption / desorption

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

The adsorption coefficient (Koc) of the test material has been determined to be in the range log10Koc 5.49 to >5.63.

Key value for chemical safety assessment

Koc at 20 °C:
427 000

Additional information

ADSORPTION COEFFICIENT

Method

The determination was carried out using the HPLC screening method, Method C19 of Commission Directive 2001/59/EC (which constitutes Annex V of Council Directive 67/548/EEC).

Results

The retention times, capacity factors and log10Kocvalues determined for the sample are shown in the table below:

Component

Injection

Retention Time (mins)

Capacity Factor (K)

log10K

log10Koc

Koc

Trimer

1

25.425

10.366

1.016

5.49

3.06 x 105

2

25.284

10.303

1.013

5.48

Tetramer

1

43.370

18.388

1.265

>5.63

>4.27 x 105

2

42.924

18.188

1.260

>5.63

Pentamer

1

77.681

33.726

1.528

>5.63

>4.27 x 105

2

76.760

33.314

1.523

>5.63

Conclusion

The adsorption coefficient (Koc) of the test material has been determined to be in the range 3.06 x 105to >4.27 x 105, log10Koc5.49 to >5.63.

[LogKoc: 5.63]