Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
November 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
The study was conducted according to an internationally recognised method. No deviation was reported. Test substance is adequately specified. Therefore full validation applies

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2020
Report date:
2020

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
not specified
Principles of method if other than guideline:
N/A
GLP compliance:
no
Type of method:
effusion method: Knudsen cell

Test material

Constituent 1
Reference substance name:
Enzymatic hydrolyis products of Candida Saitoana
EC Number:
952-608-9
IUPAC Name:
Enzymatic hydrolyis products of Candida Saitoana
Test material form:
solid: particulate/powder
Details on test material:
- Appearance: Yellow powder
- Storage In darkness at room temperature
- Batch: 19246
- Manufacturing date: September 2019
- Expiry date: September 2021

Results and discussion

Vapour pressure
Key result
Temp.:
ca. 30 °C
Vapour pressure:
< 0.001 Pa
Remarks on result:
not determinable because of methodological limitations
Remarks:
The vapour pressure of the test item was considered to be lower than 10-3 Pa at 30 °C and as a consequence largely lower than 10-3 Pa at 20 °C. This value of 10-3 Pa corresponds to the minimal limit of pressure determined by our apparatus.

Applicant's summary and conclusion

Conclusions:
The vapour pressure of the test item was considered to be lower than 10-3 Pa at 30 °C and as a consequence largely lower than 10-3 Pa at 20 °C.
Executive summary:

The vapour pressure of the test substance was measured according to OECD 104 / EU A4 guideline using a effusion method weight loss.

The vapour pressure of the test item was considered to be lower than 10-3 Pa at 30 °C and as a consequence largely lower than 10-3 Pa at 20 °C.