Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
effusion method: Knudsen cell

Test material

Constituent 1
Reference substance name:
Grape, red, ext.
EC Number:
284-511-6
EC Name:
Grape, red, ext.
Cas Number:
84929-27-1
IUPAC Name:
5-[(1E)-2-(4-hydroxyphenyl)ethenyl]benzene-1,3-diol; 5-[(2R,3R)-6-hydroxy-2-(4-hydroxyphenyl)-4-[(1E)-2-(4-hydroxyphenyl)ethenyl]-2,3-dihydro-1-benzofuran-3-yl]benzene-1,3-diol
Test material form:
solid

Results and discussion

Vapour pressure
Key result
Temp.:
ca. 60 °C
Vapour pressure:
ca. 0.003 Pa

Applicant's summary and conclusion

Conclusions:
According to attached study report, the Vapour Pressure of Palmitoyl grapevine shoot extract is 3.41E10-3 Pa at 60°C.
Executive summary:

The vapour pressure of Palmitoyl grapevine shoot extract was determined according to OECD 104 resp. EU A.4 using the effusion method (weight loss).

Vapour pressure was examined at nine different temperatures. No temperatures could be evaluated as they showed no reproducible or relevant weight loss.

As a calculation on base of the measured weight losses is not possible, the highest vapour pressure, derived from all measurements, is stated as limit value.

Vapour pressure at 60 °C: 3.41* 10-03 Pa