Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
02 Apr 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Cross-reference
Reason / purpose for cross-reference:
reference to same study
Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
other information
Study period:
02 Apr 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Reason / purpose for cross-reference:
reference to same study
Qualifier:
no guideline followed
Principles of method if other than guideline:
Determination of the specific surface area by BET
GLP compliance:
no
Type of method:
other: Brunauer, Emmet and Teller (BET) method for determination of surface area

The result of specific surface area were as follows:

Mass of dried cell (g): 10.4974

Mass of dried cell and test item after degassed (g): 10.9096

Mass of degassed test item (g): 0.4122

C constant: 64.5047

Specific surface area of test item (m²/g): 15

 

 

Conclusion

Specific surface area of the fibre in batch No. 15-11-519 was determined to be 15 m²/g.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2019
Report date:
2019

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions) - Method B: Fibre Length and Diameter Distributions
Deviations:
no
GLP compliance:
no
Type of method:
determination of fibre length and diameter distributions
Remarks:
by scanning electron microscopy (SEM)

Test material

Constituent 1
Chemical structure
Reference substance name:
Vapour grown graphitic carbon fibre
Molecular formula:
C
IUPAC Name:
Vapour grown graphitic carbon fibre

Results and discussion

Particle size
Remarks on result:
other: see "Any other information on results incl. tables"

Any other information on results incl. tables

The average of fibre length, diameter and aspect ratio (length/diameter) of the fibre in the test item (Batch No. 15-11-519) is shown in the following table:

 

 

Fibre length

Fibre diameter

Average of aspect ratio

Average

Average

D50

≤100 nm

[µm]

[nm]

[nm]

[%]

[-]

Average

5.2

148

143

18.5

35

Range

1.8-20

48-372

-

-

-

 

 

The fibres from 5 production batches, including batch No. 15-11-519, were also observed by SEM. The average and standard deviation of fibre length, diameter and aspect ratio are shown in the following table:

 

 

Fibre length

Fibre diameter

Average of aspect ratio

Average

Average

≤100 nm

[µm]

[nm]

[%]

[-]

15-09-435

3.7

152

11.0

24

15-11-519

5.2

148

18.5

35

17-01-009

4.7

146

8.0

32

17-01-034

3.8

142

21.5

27

18-02-120

4.0

161

9.0

25

Average of 5 batches

Average

4.3

150

13.6

29

SD

0.6

7

6.0

5

Min

3.7

142

8.0

24

Max

5.2

161

21.5

35

 

 

Conclusion

Two hundreds of fibre for batch No. 15-11-519 is measured for its length and diameter. The range and average of fibre length of batch No. 15-11-519 were 1.8 - 20 µm and 5.2 µm, respectively. The range and average of fibre diameter were 48 - 372 nm and 148 nm, respectively. 18.5 % of the particles had a diameter ≤100 nm. The average of the aspect ratio was 35.

The average of 5 production batches for average fibre length, average fibre diameter and average of aspect ratio were 4.3 µm, 150 nm and 29, respectively. In the 5 batches the percentage of particles ≤100 nm ranged from 8.0 % to 21.5 % (13.6 % average).

Applicant's summary and conclusion

Conclusions:
The average fibre length, fibre diameter and aspect ratio were 4.3 µm, 150 nm and 29, respectively. The percentage of particles ≤100 nm ranged from 8.0 % to 21.5 % (13.6 % average).