Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
15 Feb to 05 Mar 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
GLP compliance:
yes (incl. QA statement)
Remarks:
Department of Health of the Government of the United Kingdom, Medicines and Heathcare products Regulatory Agency (MHRA)
Auto-ignition temperature:
294 °C
Atm. press.:
103.1 kPa

Results

Temperature (ºC)

Clean Flask (Yes/No)

Volume (µL)

Ignition Delay (s)

Observations

200

Yes

70

>300

No ignition. Grey fumes were emitted.

250

Yes

70

>300

No ignition. Grey fumes were emitted.

300

Yes

70

>300

No ignition. Grey fumes were emitted.

350

No

70

>300

No ignition. Grey fumes were emitted.

400

No

70

2

A yellow flame. Grey fumes were emitted.

380

Yes

70

3

A yellow flame. Grey fumes were emitted.

370

Yes

70

4

A yellow flame. Grey fumes were emitted.

360

Yes

70

4

A yellow flame. Grey fumes were emitted.

358

Yes

70

4

A yellow flame. Grey fumes were emitted.

354

No

70

5

A yellow flame. Grey fumes were emitted.

352

No

70

5

A yellow flame. Grey fumes were emitted.

350

Yes

70

>300

No ignition. Grey fumes were emitted.

350

Yes

200

5

A yellow flame. Grey fumes were emitted.

348

Yes

200

5

A yellow flame. Grey fumes were emitted.

344

Yes

200

6

A yellow flame. Grey fumes were emitted.

342

Yes

200

>300

No ignition. Grey fumes were emitted.

342

Yes

400

7

A yellow/red flame. Grey fumes and soot were emitted.

340

Yes

400

6

A yellow/red flame. Grey fumes and soot were emitted.

338

Yes

400

7

A yellow/red flame. Grey fumes and soot were emitted.

336

Yes

400

7

A yellow/red flame. Grey fumes and soot were emitted.

334

Yes

400

8

A yellow/red flame. Grey fumes and soot were emitted.

332

Yes

400

8

A yellow/red flame. Grey fumes and soot were emitted.

330

Yes

400

9

A yellow/red flame. Grey fumes and soot were emitted.

328

Yes

400

9

A yellow/red flame. Grey fumes and soot were emitted.

326

Yes

400

11

A yellow/red flame. Grey fumes and soot were emitted.

324

Yes

400

11

A yellow/red flame. Grey fumes and soot were emitted.

322

Yes

400

11

A yellow/red flame. Grey fumes and soot were emitted.

320

Yes

400

10

A yellow/red flame. Grey fumes and soot were emitted.

310

Yes

400

16

A yellow/red flame. Grey fumes and soot were emitted.

308

Yes

400

17

A yellow/red flame. Grey fumes and soot were emitted.

300

Yes

400

24

A yellow/red flame. Grey fumes and soot were emitted.

298

Yes

400

26

A yellow/red flame. Grey fumes and soot were emitted.

290

Yes

400

>300

No ignition. Grey fumes were emitted.

292

Yes

400

>300

No ignition. Grey fumes were emitted.

294

Yes

400

>300

No ignition. Grey fumes were emitted.

296

Yes

400

31

A yellow/red flame. Grey fumes and soot were emitted.

294

Yes

600

177

A yellow/red flame. Grey fumes were emitted.

292

Yes

600

>300

No ignition. Grey fumes were emitted.

292

Yes

800

>300

No ignition. Grey fumes were emitted.

292

Yes

1000

>300

No ignition. Grey fumes were emitted.

292

Yes

200

>300

No ignition. Grey fumes were emitted.

 

Room temperature: 17 to 19 °C

Atmospheric pressure: 99.8 to 103.1 kPa

 

Conclusion

The test item has been determined to have an auto-ignition temperature of 294 °C.

Description of key information

Auto-ignition temperature: 294 °C (EU Method A.15)

Key value for chemical safety assessment

Autoflammability / Self-ignition temperature at 101 325 Pa:
294 °C

Additional information