Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Guideline study without deviations; read across approach
Qualifier:
according to guideline
Guideline:
ISO No., other: Cleveland open cup
GLP compliance:
yes
Type of method:
open cup
Flash point:
> 104 °C
Remarks on result:
other: At approximately 104 ° C the sample foamed intensively (over the rim of the test vessel). Therefore the measurement of the flash point was aborted.
Conclusions:
The flash point of the test substance cannot be determined with the Cleveland method. At approximately 104 °C the sample foamed intensively. Therefore the measurement of the flasshpoint was aborted.
Executive summary:

The flash point of the test substance cannot be determined with the Cleveland open cup method. At approximately 104 °C the sample foamed intensively. Therefore the measurement of the flashpoint was aborted.

Description of key information

The flash point of the source substance cannot be determined with the Cleveland open cup method. At approximately 104 °C the sample foamed intensively. Therefore the measurement of the flashpoint was aborted. The same result can be expected for the target substance.

Key value for chemical safety assessment

Additional information