Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
01 June 2017 to 06 July 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
not specified
Principles of method if other than guideline:
Called "ATZ INT 000002" in attached report.
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)

Test material

Constituent 1
Chemical structure
Reference substance name:
3-amino-N,N,N-trimethylanilinium trichlorozincate(1-)
Cas Number:
53831-80-4
Molecular formula:
C9H15Cl3N2Zn
IUPAC Name:
3-amino-N,N,N-trimethylanilinium trichlorozincate(1-)
Test material form:
solid: particulate/powder
Specific details on test material used for the study:
Called "ATZ INT 000002" in attached report.

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Moisture (wt %):
5.59
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
Remarks:
Sample melted. Not flammable, no further ignitability testing required.

Applicant's summary and conclusion

Interpretation of results:
not classified based on GHS criteria
Conclusions:
Sample melted. Not flammable, no further ignitability testing required.

Not classified based on GHS criteria.
Executive summary:

Testing carried out to Amethod A.10 Flammability (solids) according to EU Regulation No 440/2008.

Sample melted. Not flammable, no further ignitability testing required.

Not classified based on GHS criteria.