Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
24 June 2021
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Referenceopen allclose all

Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018
Reference Type:
study report
Title:
Unnamed
Year:
2021
Report date:
2021

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Qualifier:
according to guideline
Guideline:
ISO No., other: 11018
Version / remarks:
1997
GLP compliance:
not specified
Remarks:
1 test in GLP and 1 test in non GLP
Type of method:
equilibrium method closed cup
Flash point apparatus:
other: Normalab NPV 310 - This apparatus is in compliance with the following standard: ISO Standard 3679 (September 2004)

Test material

Constituent 1
Reference substance name:
Thuya occidentalis, ext.
EC Number:
290-370-1
EC Name:
Thuya occidentalis, ext.
Cas Number:
90131-58-1
Molecular formula:
not relevant for a UVCB substance
IUPAC Name:
Essential oil of thuya occidentalis obtained from leaves by steam distillation
Test material form:
liquid
Specific details on test material used for the study:
batch number 5087 - production date : 2018 january
batch number n° N° 6967R-2 : 2021

Results and discussion

Flash pointopen allclose all
Key result
Flash point:
62 °C
Atm. press.:
97.3 kPa
Key result
Flash point:
58 °C
Atm. press.:
101.3 kPa

Applicant's summary and conclusion

Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
According to the variability of the sample due to fact that it is an UVCB (essential oil) the flash point of the test item was in the worst case 58 °C ± 1 °C.

Executive summary:

The flash point of the test substance was determined under ISO 11018 method of 1997.

The flash point is below the classification thresholds of 60°C of the CLP regulation 1272/02008. Therefore the susbstance is classified as flammable liquids category 3.