Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Melting point / freezing point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Version / remarks:
adopted 1995
Deviations:
no
GLP compliance:
no
Type of method:
differential scanning calorimetry
Key result
Melting / freezing pt.:
> 650 °C
Atm. press.:
1 013 hPa
Decomposition:
yes
Decomp. temp.:
>= 650 °C
Remarks on result:
other: No melting point was determined prior to the decomposition and/or sublimation of the test item , starting at approx. 650°C
Conclusions:
No melting point was determined prior to the decomposition and/or sublimation of the test item, starting at approx. 650°C.
Executive summary:

The DSC measurement was combined with a thermogravimetric (TG) measurement according to OECD Test Guideline 102 [adopted on 27 July 1995] and EU test method A.1 “Melting/freezing temperature“, Council Regulation (EC) No 440/2008 of 30 May 2008.

The heat flow curve shows a very small endothermic peak at 228°C (226°C extrapolated onset), which corresponds to the melting point of tin (230°C). Upon further heating a larger endothermic effect is registered starting at 747°C, with a peak maximum temperature at 858°C. Simultaneously to the endothermic heat flow, however, a significant mass loss is observed. After cooling down, the sample holder, the reference crucible as well as the sample crucible are covered with a grey precipitation (sample crucible inside and outside). Therefore the endothermic peak cannot be related to melting, but to decomposition and/or sublimation. 

Description of key information

No melting point was determined prior to the decomposition and/or sublimation of the test item, starting at approx. 650°C.

Key value for chemical safety assessment

Additional information

No melting point was determined prior to the decomposition and/or sublimation of the test item, starting at approx. 650°C.