Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
skin corrosion: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2005-03-02
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Only basic information given.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2005

Materials and methods

Test guideline
Qualifier:
no guideline available
Principles of method if other than guideline:
Corrositex TM is a quantitative in vitro corrosivity test. The model is based on the time required for the test substance to pass through a biobarrier membrane and produce a change in a chemical detection system.
GLP compliance:
not specified

Test material

Constituent 1
Chemical structure
Reference substance name:
Aluminium lithium tri-tert-butoxide hydride
EC Number:
241-490-8
EC Name:
Aluminium lithium tri-tert-butoxide hydride
Cas Number:
17476-04-9
Molecular formula:
C12H28AlO3.Li
IUPAC Name:
aluminium lithium tri-tert-butoxide hydride
Details on test material:
- Name of test material: Lithium tri-tert-butoxyaluminum hydride (TBLAH) in tetrahydrofuran (THF)
- Purity: 26.9 %; Tetrahydrofuran (THF): 13 %
- Lot. No: 180-066

In vitro test system

Test system:
artificial membrane barrier model

Results and discussion

In vitro

Results
Irritation / corrosion parameter:
other: Mean Breakthrough time
Vehicle controls validity:
not applicable
Negative controls validity:
not applicable
Positive controls validity:
not specified
Remarks on result:
other: Mean Breakthrough time of 119:68 min wwas observed

Any other information on results incl. tables

One run has been performed with 4 replicates. Each run was longer than > 60 minutes. A mean breakthrough time of the 4 replicates of 119.68 minutes was determined. Based on the results of the Corrositex TM Assay, the test article has not to be classified as corrosive according to the UN Dangerous Goods Transport Regulations.

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The test substance was tested for corrosive properties in the Corrositex TM Assay. Under the conditions of this test, the test substance was found to be not corrosive.
Executive summary:

The test substance was tested for corrosive properties in the Corrositex TM Assay in a single trial (four replicates) that examines the mean breakthrough time in order to determine the packing group classification. The substance was considered as categroy 2 substance and therefore tested according to Category 2 test criteria. The mean breakthrough time of the 4 replicates was 119.68 (> 60 minutes), therefore, based on the evaluation of the test results the test substance was not considered to be corrosive.