Administrative data

Endpoint:
explosiveness
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because there are no chemical groups present in the molecule which are associated with explosive properties
Justification for type of information:
Statement:
None of the components of the test substance does contain chemical groups which are associated with explosive properties. The test substance contains 2.32% water, which has no explosive properties. The molecular structures of impurities at ≤ 1% were not taken into account.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report date:
2015

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
other: UN ST/SG/AC.10/11/Rev.5: Recommendations on the Transport of Dangerous Goods, Manual of Tests and Criteria, Appendix 6 "Screening procedures" (2009)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Version / remarks:
(2008)
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
3,3,4,4,5,5,6,6,7,7,8,8,8-tridecafluorooctane-1-thiol
EC Number:
628-448-8
Cas Number:
34451-26-8
Molecular formula:
C8H5F13S
IUPAC Name:
3,3,4,4,5,5,6,6,7,7,8,8,8-tridecafluorooctane-1-thiol
Details on test material:
- Name of the substance (as cited in study report): NS-1000

Results and discussion

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
From a GLP-compliant statement based on structural features, it was concluded that the substance NS-1000 has no explosive properties.