Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Study well documented and scientifically acceptable
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 107 (Partition Coefficient (n-octanol / water), Shake Flask Method)
GLP compliance:
no
Type of method:
shake-flask method to: flask method
Partition coefficient type:
octanol-water
Analytical method:
gas chromatography
Type:
log Pow
Partition coefficient:
0.58
Temp.:
25 °C
pH:
10
Conclusions:
The LogPow value amounts to 0.58 (at 25 °C and pH 10).
Executive summary:

The octanol-water partition coefficient of the substance Butyldiethanolamine was experimentally investigated according to standard methods (shake-flask method) equivalent to OECD Guideline 107 without GLP compliance (BASF AG, 1993). Three different concentrations were measured individually. Monitoring of substance concentrations by GC took place in both equilibrium phases. The LogPow value was determined to be 0.58 (at 25 °C and pH 10).

Description of key information

Octanol-water partition coefficient_logPow_method equivalent to OECD 107: 0.58 at 25 °C (pH 10)

Key value for chemical safety assessment

Log Kow (Log Pow):
0.58
at the temperature of:
25 °C

Additional information

The octanol-water partition coefficient of the substance Butyldiethanolamine was experimentally investigated according to standard methods (shake-flask method) equivalent to OECD Guideline 107 without GLP compliance (BASF AG, 1993). Three different concentrations were measured individually. Monitoring of substance concentrations by GC took place in both equilibrium phases. The LogPow value was determined to be 0.58 (at 25 °C and pH 10).