Physical & Chemical properties

Explosiveness

Currently viewing:

Administrative data

Endpoint:
explosiveness
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Basic data given (comparable to guidelines/standards)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2003
Report date:
2003

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Deviations:
yes
Remarks:
The test report gives no detailed information about: 1) purityof the test substance, 2) reference substance, 3) observations for the thermal sensitivity tests
GLP compliance:
not specified

Test material

Constituent 1
Chemical structure
Reference substance name:
4-chloroaniline
EC Number:
203-401-0
EC Name:
4-chloroaniline
Cas Number:
106-47-8
Molecular formula:
C6H6ClN
IUPAC Name:
4-chloroaniline
Details on test material:
- Name of test material (as cited in study report): p-Chloranilin
- Analytical purity: not reported
-Physical state: solidified melt

Results and discussion

Small-scale preliminary testsopen allclose all
Parameter:
other: More sensitive to shock than m-dinitrobenzene
Remarks:
migrated information
Remarks on result:
not measured/tested
Parameter:
other: More sensitive to friction than m-dinitrobenzene
Remarks:
migrated information
Remarks on result:
not measured/tested
Parameter:
other: Explosive under influence of flame
Remarks:
migrated information
Remarks on result:
not measured/tested

Any other information on results incl. tables

Results from the mechanical sensitivity (shock) test:

6 from 6 experiments negativ

Applicant's summary and conclusion