Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Guideline:
ISO No., other: ASTM D 92
GLP compliance:
no
Type of method:
open cup
Remarks:
Cleveland open cup
Flash point:
ca. 190 °C
Atm. press.:
ca. 1 013 hPa
Remarks on result:
other: Pressure was not reported. Data is estimated, because the test was conducted under ambient condition using an open cup system.
Endpoint:
flash point
Type of information:
not specified
Adequacy of study:
supporting study
Reliability:
4 (not assignable)
Rationale for reliability incl. deficiencies:
other: Only short abstract available
Principles of method if other than guideline:
company data, no information is given on test method
GLP compliance:
not specified
Type of method:
other: not specified
Flash point:
ca. 176.3 °C
Remarks on result:
other: Company data, data on pressure was not specified.

Description of key information

ca. 190 °C at 1013 hPa

Key value for chemical safety assessment

Flash point at 101 325 Pa:
190 °C

Additional information

The flash point is determined using Cleveland open cup method (ASTM D 92). This result is supported by another company data.