Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Emergency measure - Inhalation: Remove affected person to fresh air.
Emergency measure - Eyes: Immediately rinse eyes thoroughly with running water while
holding the eyelids open.
Emergency measure - Skin: Remove contaminated clothing. Rinse contaminated skin with
water using soap if available.
Emergency measure - Ingestion: Clean mouth with water and subsequently drink plenty of
water. Obtain medical assistance.

Fire-fighting measures

Recommended extinguishing agent: Water spray, carbon dioxide, dry chemical powder or polymer
foam.

Product arising from burning: Toxic fumes containing oxides of Carbon and Nitrogen.

Product determined by test: N

Protective equipment: Safety goggles and disposable gloves must be worn. Also a
breathing apparatus or other protective equipment (e.g.
positive pressure supplied air respirator) to ensure
respiratory protection must be used.

Accidental release measures

Emergency measures in case of spillage: In the event of spillage, collect the material in dry form
(wearing suitable protective equipment / clothing) and
incinerate in the site solid waste incinerator which is
specifically licenced for that purpose.

Handling and storage

Handling: Proper chemical handling procedures must be adopted. Use
good personal hygiene practices. Avoid dust
generation. Suitable respiratory protective equipment (full
facemask with ABEK filter - EN146) must be worn if there is
any potential for exposure to dust. Safety spectacles,
disposable gloves (EN 374) and suitable protective
clothing must be worn (Tyvek classic suit -EN 465, EN1149).
Precautionary measures must be taken against static
discharges. Avoid sources of ignition.

An LEV is utilised in the form of a laminar flow unit which
has a flow velocity of 2 meters per second.

Storage: Store in accordance with standard storage regulations.
Sealed in PE bags placed in fibre drums. Storage
temperature between 0 and 20°C. Protected from direct
sunlight and excessive temperatures.

Packaging of the substance and or preparation: 100 l fibreboard drums with polyethylene liners.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport: Not classified as dangerous for transport
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: Avoid contact with oxidising agents.

Chemical reaction with water: No reaction

Dust explosion: A dust explosion test was performed in the 20 l ball with
10000 J. The explosion which was observed afterwards was
graded 1 (out from gradings 1 to 3, with 3 being the
heaviest explosion). The pressure produced by this explosion
was determined to be 8.2 bar, Kst: 163 bar*m*s-1.

Dust explosion determined by test: Y

Disposal considerations

Industry - Possibility of recovery/recycling: Recovery by mechanical collection.

Industry - Possibility of neutralisation: Not possible

Industry - Possibility of destruction: controlled discharge: Not possible. Removal in treatment plant or landfill not
recommended.

Industry - Possibility of destruction - incineration: Incinerate in an approved furnace with combustion gas
scrubbing and emission gas control. Scrubber water to be
treated in a WWTP.

Industry - Possibility of destruction - water purification: Not recommended

Industry - Possibility of destruction - other: Not applicable

Public at large - Possibility of recovery/recycling: Not applicable. The substance is not available for the
public at large.

Public at large - Possibility of neutralisation: Not applicable

Public at large - Possibility of destruction: controlled discharge: Not applicable

Public at large - Possibility of destruction - incineration: Not applicable

Public at large - Possibility of destruction - water purification: Not applicable

Public at large - Possibility of destruction - others: none