Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
25 Aug 2015 to 16 Sept 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: similar to guideline study under CLP
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Version / remarks:
2012
Qualifier:
according to guideline
Guideline:
other: DIN 51562
Version / remarks:
part I 1999
GLP compliance:
yes (incl. QA statement)
Type of method:
capillary viscometer (static)
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
1.456
Key result
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
1.107

 





























































Measurements



At 20 °C



At 40 °C



1strun



297.91



390.46



2ndrun



298.69



389.62



3rdrun



296.97



390.03



4thrun



296.96



390.50



5thrun



297.96



392.52



Mean value of flow time (s)



297.698



390.626



Hagenbach correction (s)



0.355



0.489



Corrected flow time (s)



297.343



390.137



Viscometer constant (mm2s-2)*



0.004896



0.002837



Kinematic viscosity (mm2s-1)



1.456



1.107



*Different capillaries were used at 20 °C and 40 °C, resulting in different flow times

Conclusions:
The kinematic viscosity of the substance is 1.456 mm²/s at 20 °C and 1,107 mm²/s at 40 °C
Executive summary:

The kinematic viscosity of the substance is 1.456 mm²/s at 20 °C and 1.107 mm²/s at 40 °C when tested in a capillary viscometer.

Description of key information

 The kinematic viscosity at 40 °C is < 7 mm²/s according to the SDS. This is confirmed in a study which showed a kinematic viscosity of 1.456 mm²/s at 20 °C and 1,107 mm²/s at 40 °C.

Key value for chemical safety assessment

Viscosity:
1.456 mm²/s (static)
at the temperature of:
20 °C

Additional information