First-aid measures

"Inhalation : No treatment necessary under normal conditions of use. If symptoms persist, obtain medical advice.


Skin Contact : Remove contaminated clothing. Flush exposed area with water and follow by washing with soap if available.


Eye Contact : Immediately flush eyes with large amounts of water for at least 15 minutes while holding eyelids open. Transport to the


nearest medical facility for additional treatment.


Ingestion : In general no treatment is necessary unless large quantities are swallowed, however, get medical advice."

Fire-fighting measures

"Clear fire area of all non-emergency personnel.


Specific Hazards : Carbon monoxide may be evolved if incomplete combustion occurs.


Extinguishing Media : Alcohol-resistant foam, water spray or fog. Dry chemical powder, carbon dioxide, sand or earth may be used for small


fires only.


Unsuitable Extinguishing Media : Do not use water in a jet.


Protective Equipment for Firefighters : Wear full protective clothing and self-contained breathing apparatus.


Additional Advice : Keep adjacent containers cool by spraying with water."

Accidental release measures

"Observe all relevant local and international regulations.


Protective measures : Avoid contact with spilled or released material. Immediately remove all contaminated clothing.


Use the following as appropriate: Notify authorities if any exposure to the general public or the environment occurs or is likely to occur.


Local authorities should be advised if significant spillages cannot be contained. Keep animals off contaminated vegetation. Stay upwind and keep out of low areas. Be ready for fire or possible exposure. Prevent from spreading or entering into drains, ditches or rivers by using sand, earth, or


other appropriate barriers. Use appropriate containment to avoid environmental contamination. Ventilate contaminated area thoroughly.


Clean Up Methods : For large liquid spills (> 1 drum), transfer by mechanical means such as vacuum truck to a salvage tank for recovery or safe


disposal. Do not flush away residues with water. Retain as contaminated waste. Allow residues to evaporate or soak up with an appropriate absorbent material and dispose of safely.


Remove contaminated soil and dispose of safely.


For small liquid spills (< 1 drum), transfer by mechanical means to a labelled, sealable container for product recovery or safe


disposal. Allow residues to evaporate or soak up with an appropriate absorbent material and dispose of safely. Remove


contaminated soil and dispose of safely."

Handling and storage

"General Precautions : Avoid breathing vapours or contact with material. Only use in well ventilated areas. Wash thoroughly after handling.  Use the


information in this data sheet as input to a risk assessment of local circumstances to help determine appropriate controls for safe handling, storage and disposal of this material.


Handling : Avoid contact with skin, eyes, and clothing. Do not empty into drains.


Storage : Bulk storage tanks should be diked (bunded). Keep away from flammables, oxidizing agents, and corrosives. Vapours from tanks should not be released to atmosphere. Breathing losses during storage should be controlled by a suitable vapour treatment system. Nitrogen blanket recommended for large tanks (capacity 100 m3 or higher). Storage Temperature : 50°C


maximum. Insulation (lagging) will minimize heat loss in areas of low ambient temperature. Tanks should be fitted with


heating coils in areas where ambient conditions can result in handling temperatures below the freezing point/pour point of


the product.


Product Transfer : Keep containers closed when not in use. Do not use


compressed air for filling, discharging or handling.


Recommended Materials : Stainless steel. Epoxy resins. Polyester.


Unsuitable Materials : Aluminium. Copper. Copper alloys.


Container Advice : Containers, even those that have been emptied, can contain explosive vapours. Do not cut, drill, grind, weld or perform


similar operations on or near containers.


Additional Information : Ensure that all local regulations regarding handling and storage facilities are followed."

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
UN 3082
Shippingopen allclose all
Labels:
9
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
UN 3082
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shipping information
Proper shipping name and description:
ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S. (Alcohol C12-C16 Poly (1-6) Ethoxylate)
Chemical name:
ALCOHOL C12-C16 POLY (1-6) ETHOXYLATE)
Class or division:
Class 9: Miscellaneous dangerous substances and articles, including environmentally hazardous substances
Marine pollutant
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

"Occupational Exposure Limits UK Workplace Exposure Limits None established.


Additional Information : Wash hands before eating, drinking, smoking and using the toilet. Launder contaminated clothing before re-use.


Exposure Controls : The level of protection and types of controls necessary will vary depending upon potential exposure conditions.


Select controls based on a risk assessment of local circumstances.


Appropriate measures include: Adequate ventilation to control airborne concentrations. Local exhaust ventilation is recommended. Eye washes and showers for emergency use.


Personal Protective Equipment: Personal protective equipment (PPE) should meet recommended national standards. Check with PPE suppliers.


Respiratory Protection : Select a filter suitable for combined particulate/organic gases and vapours [boiling point >65 °C (149 °F)] meeting EN141


(AS/NZS:1716).


If engineering controls do not maintain airborne concentrations to a level which is adequate to protect worker health, select respiratory protection equipment suitable for the specific conditions of use and meeting relevant legislation. Check with respiratory protective equipment suppliers. Where air-filtering respirators are suitable, select an appropriate combination of mask and filter. Where air-filtering respirators are unsuitable


(e.g., airborne concentrations are high, risk of oxygen deficiency, confined space) use appropriate positive pressure breathing apparatus.


Hand Protection : Where hand contact with the product may occur the use of gloves approved to relevant standards (e.g. Europe: EN374,


US: F739, AS/NZS:2161) made from the following materials may provide suitable chemical protection: Incidental contact/Splash protection: Nitrile rubber gloves Suitability and durability of a glove is dependent on usage, e.g. frequency and duration of contact, chemical resistance of glove


material, glove thickness, dexterity. Always seek advice from glove suppliers. Contaminated gloves should be replaced. Personal hygiene is a key element of effective hand care.


Gloves must only be worn on clean hands. After using gloves, hands should be washed and dried thoroughly. Application of a non-perfumed moisturizer is recommended. Eye Protection : Chemical splash goggles (chemical monogoggles). Approved to EU Standard EN166, AS/NZS:1337.


Protective Clothing : Chemical resistant gloves/gauntlets, boots, and apron (where risk of splashing). Monitoring Methods : Monitoring of the concentration of substances in the breathing zone of workers or in the general workplace may be required to confirm compliance with an OEL and ade quacy of exposure controls. For some substances biological monitoring may also


be appropriate. Examples of sources of recommended air monitoring methods are given below or contact supplier.


Health and Safety Executive (HSE), UK: Methods for the Determination of Hazardous Substances, http://www.hsl.gov.uk/search.htm.


Berufsgenossenschaftliches Institut für Arbeitssicherheit (BIA), Germany http://www.hvbg.de/d/bia/index.html. L'Institut


National de Recherche et de Securité, (INRS), France http://www.inrs.fr/securite/hygiene_securite_travail.html. Environmental Exposure


Controls : Where material is heated, sprayed or mist formed, there is greater potential for airborne concentrations to be generated."

Stability and reactivity

"Stability : Oxidises on contact with air. Stable up to 50 degrees C Conditions to Avoid : Temperatures above 50°C


Materials to Avoid : Copper. Copper alloys. Aluminium. Strong oxidising agents.


Hazardous Decomposition Products : None expected under normal use conditions."

Disposal considerations

"Material Disposal : Recover or recycle if possible. It is the responsibility of the waste generator to determine the toxicity and physical


properties of the material generated to determine the proper waste classification and disposal methods in compliance with


applicable regulations. Do not dispose into the environment, in drains or in water courses. Waste product should not be allowed to contaminate soil or water. Container Disposal : Drain container thoroughly. After draining, vent in a safe place away from sparks and fire. Residues may cause an explosion hazard. Do not puncture, cut or weld uncleaned drums. Send to drum recoverer or metal reclaimer. Local Legislation : Disposal should be in accordance with applicable regional, national, and local laws and regulations. Local regulations may  be more stringent than regional or national requirements and must be complied with."