Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
18 October 2010 - 3 November 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: CIPAC MT187
Qualifier:
according to guideline
Guideline:
other: ISO 13320-1
GLP compliance:
yes
Type of distribution:
volumetric distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
Cobalt wolframate
EC Number:
233-254-8
EC Name:
Cobalt wolframate
Cas Number:
10101-58-3
Molecular formula:
CoO4W
IUPAC Name:
cobalt wolframate
Details on test material:
- Name of test material (as cited in study report): Cobalt wolframate
- Physical state: solid

Results and discussion

Particle sizeopen allclose all
Percentile:
D50
Mean:
12.5 µm
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Percentile:
D10
Mean:
1.6 µm
Percentile:
D50
Mean:
12.5 µm
Percentile:
D90
Mean:
246.4 µm

Any other information on results incl. tables

See attachment

Applicant's summary and conclusion

Conclusions:
The median particle size L50 of the test items deduced from the particle size distributions is 12.5 um
The particle size L10 of the test items deduced from the particle size distributions is 1.6 um
The particle size L90 of the test items deduced from the particle size distributions is 246.4 um
Executive summary:

The particle size distribution (volume distribution) of the test item was measured by laser diffraction with dry dispersing.

The median particle size L50 of the test items deduced from the particle size distributions is 12.5 um.

The particle size L10 of the test items deduced from the particle size distributions is 1.6 um.

The particle size L90 of the test items deduced from the particle size distributions is 146.2 um