Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
January 2001
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2001
Report date:
2001

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
methyl 10-methoxy-5H-dibenzo[b,f]azepine-5-carboxylate
Cas Number:
353497-37-7
Molecular formula:
C17 H15 N O3
IUPAC Name:
methyl 10-methoxy-5H-dibenzo[b,f]azepine-5-carboxylate
Details on test material:
Appearance: white to yellowish powder
expiry date: 1. march 2002

Results and discussion

Flammable solids
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Remarks on result:
other: no ignition
Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

The test substance could not be ignited, although it emitted yellow sparks and melted in contact with the ignition source. After removal of the ignition source, no more sparks were observed. The molten test substance turned brown,

Applicant's summary and conclusion

Conclusions:
In conclusion, the test substance is not highly flammable according to the criteria of the Directive.