Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
23 Nov 2020 to 15 Jan 2021
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2021
Report date:
2021

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Version / remarks:
March 04, 2016
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Version / remarks:
October 2, 2012
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7300 (Density / Relative Density / Bulk Density)
Version / remarks:
June 2002
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
air comparison pycnometer (for solids)

Test material

Constituent 1
Chemical structure
Reference substance name:
3-phenyl-1H-pyrazole-4-carbaldehyde
EC Number:
632-673-7
Cas Number:
26033-20-5
Molecular formula:
C10H8N2O
IUPAC Name:
3-phenyl-1H-pyrazole-4-carbaldehyde
Test material form:
solid: particulate/powder
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Batch (Lot) Number: M19LD3723
- Purity/Composition: 103.6%
- Purity/Composition correction factor: 1.0
- Purity test date : 2020-05-04
- Expiry date: 11 November 2021 (retest date)
- Physical Description: Light yellow powder

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: At room temperature

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Final preparation of a solid: prior to use in the study, the test material was dried in a desiccator under vacuum using silicagel as the drying agent at 19.5 ± 0.9°C in dark for 96 hours.

Results and discussion

Densityopen allclose all
Key result
Type:
density
Density:
1.35 g/cm³
Temp.:
20 °C
Type:
relative density
Density:
1.35
Temp.:
20 °C

Any other information on results incl. tables

The results of the tests on the determination of the density of the test item are given in the table below.



































 



Test 1



Test 2



Test item mass (g)



3.6564



3.5362



Test item volume (cm3)



2.7173


2.7158


2.7159


2.7208


2.7155



2.6221


2.6241


2.6221


2.6220


2.6227



Mean test item volume (cm3)



2.7171 ± 0.0019



2.6226 ± 0.0008



Density [g/cm3]



1.346



1.348



Mean density [g/cm3]



1.35



The individual measurements were obtained with an accuracy of < 0.02 g/cm3. According to the guideline, the density of the test item is given as the mean value.

Applicant's summary and conclusion

Conclusions:
A gas comparison stereopycnometer was used for the determination of the density and relative density of JNJ-39125190-AAA (T003897).
The density of the test item at 20ºC was 1.35 g/cm3 (1.35E3 kg/m3).
The relative density was 1.35.