Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
25/11/2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
not specified
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
Lot Number: NEX-AC1-A01
Key result
Test procedure:
burning rate test: preliminary screening test
Moisture (wt %):
0.27
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Results of Preliminary Screening Test

Test No

Burning Time (s)

Comments

Preliminary Test

N/A

Sample melted to a dark brown liquid and emitted small quantities of smoke

 

Interpretation of results:
not classified based on GHS criteria
Conclusions:
From the preliminary screening (S/T) test the sample was seen not to ignite and therefore no further testing was required.

Classification of substance: Not highly flammable
Executive summary:

The purpose of the test is to determine the burning rate of any substance that can be ignited.

 

The test was conducted in accordance with the procedure described in EU Regulation (EC) 440/2008, Annex Part A test A10.

 

From the preliminary screening (S/T) test the sample was seen not to ignite and therefore no further testing was required.

 

Classification of substance: Not highly flammable

Description of key information

 From the preliminary screening (S/T) test the sample was seen not to ignite.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

The purpose of the test is to determine the burning rate of any substance that can be ignited.

 

The test was conducted in accordance with the procedure described in EU Regulation (EC) 440/2008, Annex Part A test A10.

 

From the preliminary screening (S/T) test the sample was seen not to ignite and therefore no further testing was required.

 

Classification of substance: Not highly flammable

Justification for classification or non-classification