Administrative data

Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: CIPAC (F) MT 12.3: ‘FLASH POINT-Pensky-Martens closed tester’
Principles of method if other than guideline:
Outline of method:
The test substance was placed in the cup of the flash point tester, with the lid closed and heated at a slow constant rate. A small flame of specified size was directed into the cup at regular intervals, then repeated to ignite the test substance in an closed cup. The flash point was taken as the lowest temperature at which application of the test flame causes the vapor above the sample to ignite.
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

Constituent 1
Chemical structure
Reference substance name:
Isooctyl palmitate
EC Number:
215-675-9
EC Name:
Isooctyl palmitate
Cas Number:
1341-38-4
Molecular formula:
C24H48O2
IUPAC Name:
6-methylheptyl hexadecanoate
Test material form:
liquid
Remarks:
a colourless liquid

Results and discussion

Flash point
Flash point:
ca. 204.8 °C
Atm. press.:
ca. 1 atm

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions: