Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
GLP compliance:
no
Type of distribution:
volumetric distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
-
EC Number:
402-480-0
EC Name:
-
Cas Number:
111850-26-1
Molecular formula:
C24H23ClN8O11S3.xK.yNa
IUPAC Name:
potassium disodium 4-({4-chloro-6-[(4-sulfophenyl)amino]-1,3,5-triazin-2-yl}amino)-2-[(E)-2-[1-ethyl-6-hydroxy-4-methyl-2-oxo-5-(sulfomethyl)-1,2-dihydropyridin-3-yl]diazen-1-yl]benzene-1-sulfonate

Results and discussion

Particle sizeopen allclose all
Percentile:
D50
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Percentile:
D50
Mean:
101.33 µm
St. dev.:
1.347
Particle size distribution at different passagesopen allclose all

Applicant's summary and conclusion

Conclusions:
The mean particle size distribution of Evercion SR7B was determined to be 101.33 um.