Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
09 February 2018 - 20 March 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
Disodium L-cystinate
EC Number:
265-025-3
EC Name:
Disodium L-cystinate
Cas Number:
64704-23-0
Molecular formula:
C6H10N2Na2O4S2.H2O
IUPAC Name:
disodium (2R)-2-amino-3-{[(2R)-2-amino-2-carboxyethyl]disulfanyl}propanoate
Test material form:
solid: particulate/powder

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
4 min
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Any other information on results incl. tables

Interpretation: If the test item does not propagate combustion along 200 mm of the pile within the 4 minutes test period the test item is considered ‘not highly flammable’.

Results: The flame of the gas burner did ignite the test item pile. The test item glowed, burned with an orange flame, emitted orange sparks and turned into a black residue. Grey smoke was observed. After removal of the ignition source, the flame extinguished after 1 second and no propagation of combustion was observed.

Applicant's summary and conclusion

Conclusions:
No propagation of combustion of the test item along 200 mm length of the pile within 4 minutes was observed. According to the guidelines, performance of the burning rate test is not required. Based on the results obtained, the test item is considered ‘not highly flammable’.
Executive summary: