Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
oxidising liquids
Remarks:
The prediction was carried out using a procedure designed to be compatible with Method A.21 Oxidising Properties (Liquids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.
Type of information:
other: Prediction
Remarks:
The prediction was carried out using a procedure designed to be compatible with Method A.21 Oxidising Properties (Liquids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.
Adequacy of study:
key study
Study period:
Experimental starting date: 21 April 2017 Experimental completion date: 04 July 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.21 (Oxidising Properties (Liquids))
Version / remarks:
The prediction was carried out using a procedure designed to be compatible with Method
A.21 Oxidising Properties (Liquids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.
Deviations:
no
GLP compliance:
no
Remarks:
Good Laboratory Practice standards are not applicable to predictions therefore no claim for compliance can be made for the oxidising properties predictions.
Specific details on test material used for the study:
Appearance/Physical state: Clear amber viscous liquid
Structure: The sponsor provided a structure on which the predictions of explosive and oxidizing properties were made. However, they wish the structure to remain confidential and therefore it has been omitted from this report.
Purity: 100% product
Expiry date: 24 June 2018
Storage conditions: Room temperature in the dark
Contact with:
other: N/A Prediction
Key result
Sample tested:
other: There were no structural alerts within the chemical structure of the test item.
Parameter:
other: There were no structural alerts within the chemical structure of the test item.
Remarks on result:
other: There were no structural alerts within the chemical structure of the test item.

There were no structural alerts within the chemical structure of the test item.

Interpretation of results:
GHS criteria not met
Remarks:
There were no structural alerts within the chemical structure of the test item.
Conclusions:
Based on the chemical structure of the test item the result for the oxidizing properties has been predicted negative.
Executive summary:

The Oxidising Properties (Liquids). Were predicted negative based on the chemical structure of the test item, using a procedure designed to be compatible with Method A.21 Oxidising Properties (Liquids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Description of key information

The Oxidising Properties (Liquids). Were predicted negative based on the chemical structure of the test item, using a procedure designed to be compatible with Method A.21 Oxidising Properties (Liquids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

No additional data.

Justification for classification or non-classification

In accordance with Regulation (EC) No 1907/2006, Annex VII, Section 7.13, Column 2, oxidising properties do not need to be investigated experimentally if there are no chemical groups associated with oxidising properties present in the molecule. The structure of the test item has been considered using a method designed to be compatible with EU Method A.21 and a valid and conclusive expert statement is available. As a result, classification of the test material as oxidising under the terms of Regulation (EC) No 1972/2008 is not required.